摘要
目的探讨精密过滤输液器对减少输液反应的效果。方法将1300例患者随机分成2组,试验组使用一次性精密过滤输液器,对照组采用普通一次性输液管,观察两组患者输液反应发生率。结果试验组无输液反应发生,对照组有5例发生输液反应,两者相比差异有统计学显著意义(P<0.05),试验组优于对照组。结论使用一次性精密过滤输液器是减少输液反应的有效措施。
Objective To investigate the effect of the precision infusion filter set on reducing infusion reaction. Methods 1 300 patients were randomly divided into 2 groups. The experimental group was used a one-time precision filter infusion set, and control group, the ordinary one-time infusion tube. The incidence of infusion reactions in the two patients were observed. Results Infusion reactions was not found in the experimental group; infusion reactions was found in 5 cases in the control group. There was statistically significant difference between two groups (P 〈 0. 05). The effect of the experimental group was better than that of the control group. Conclusion The use of one-time precision filter infusion set is an effective measure for reducing infusion reaction.
出处
《中国临床新医学》
2010年第2期193-194,共2页
CHINESE JOURNAL OF NEW CLINICAL MEDICINE
关键词
精密过滤输液器
输液反应
Precision filter infusion set