期刊文献+

Biomechanical researches on tissue engineering bone constructed by deproteinated bone 被引量:3

Biomechanical researches on tissue engineering bone constructed by deproteinated bone
原文传递
导出
摘要 Objective: To study biomechanical changes of newly formed bones 24 weeks after repairing large defects of long bones of goats using heterogeneous deproteinated bone (DPB) prepared by modified methods as an engineering scaffold. Methods: According to a fully randomized design, 18 goats were evenly divided into three groups: normal bone control group (Group A), autologous bone group (Group B) and experimental group (Group C). Each goat in Groups B and C were subjected to the periosteum and bone defect at middle-lower part of the right tibia (20% of the whole tibia in length), followed by autologous bone or DPB plus autolognus MSCs + rhBMP2 implantation, respectively and semi- ring slot fixation; while goats in Group A did not perform osteotomy. At 24 weeks after surgery, biomechanical tests were carried out on the tibias. Results: At 24 weeks after surgery, the results of anticompression test on tibias in three groups were recorded by a functional recorder presented as linear pressure-deformation curve. The shapes of the curves and their change tendency were similar among three groups. The ultimate pressure values were 10.74 MPa±1.23 MPa, 10. 11 MPa±1.35 MPa and 10.22 MPa±1.32 MPa and fracture compression rates were 26.82%±0.87%, 27.17%±0.75% and 28.22%±1.12% in Groups A, B and C, respectively. Comparisons of anti-compression ultimate pressures and fracture compression rates among three groups demonstrated no significant difference (PAB=0.415, PBC=0.494). Three-point antibend test on tibias was recorded as load-deformation curves, and the shapes of the curves and their change tendency were similar among three groups. The ultimate pressure values of the anti-bend test were 481.52 N±12.45 N, 478.34 N±14.68 N and 475.62 N±13.41 N and the fracture bend rates were 2.62 mm±0.12 mm, 2.61 mm±0.15 mm and 2.81 mm±0.13 mm in Groups A, B and C, respectively. There was no significant difference between groups (PAB=0.7, PBc=0.448). The ultimate anti-torsion torque values were 6.55 N.mi-0.25 N.m, 6.34 N'm^0.18 N'm and 6.42 N'm^0.21 N'm and fracture torsion rates were 29.51°±1.64°, 28.88±1.46° and 28.81°±1.33° in Groups A, B and C, respectively. There was no significant difference between groups (PAB=0.123, PBc=0.346). Conclusions: The biomechanical characteristics of newly formed bones from heterogeneous DPB for repairing large segmental long bone defect are comparable to those of normal bones and autologous bones. DPB has the potential for clinical usage as bone graft material.
出处 《Chinese Journal of Traumatology》 CAS 2010年第1期32-36,共5页 中华创伤杂志(英文版)
关键词 BIOMECHANICS Tissue engineering Deproteinated bone 中国人民银行 生物力学特性 变形曲线 骨髓基质细胞 力学测试 随机设计 骨移植材料 骨缺损
  • 相关文献

参考文献7

二级参考文献14

共引文献31

同被引文献19

引证文献3

二级引证文献21

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部