期刊文献+

二氧化碳在血管造影中的应用 被引量:1

原文传递
导出
摘要 血管造影技术的应用有漫长的历史,现已成为疾病诊治过程中不可缺少、不可替代的手段和方法。目前血管造影技术广泛应用含碘造影剂进行对比造影,但有些患者由于各种原因不能使用含碘造影剂。这就迫使我们必须另辟蹊径,寻找含碘造影剂的替代品。以二氧化碳(CO2)为造影剂的造影技术的诞生给我们带来新的希望,现就这项技术的发展历程和进展做一综述。
出处 《中华生物医学工程杂志》 CAS 2009年第5期402-405,共4页 Chinese Journal of Biomedical Engineering
  • 相关文献

参考文献25

  • 1Hawkins IF. Carbon dioxide digital subtraction arteriography. AJR, 1982, 139: 19-24.
  • 2Lang EV, Gossler AA, Fick LJ, et al. Carbon dioxide angiography: effect of injection parameters on bolus configuration. J Vasc Interv Radiol, 1999, 10: 41-49.
  • 3Dlaz LP, Pabon IP, Garcia JA, et al. Assessment of CO2 arteriography in arterial occlusive disease of the lower extremities. J Vasc Interv Radiol, 2000, 11: 163-169.
  • 4Liss P, Eklof H, Hellberg O, et al. Renal effects of CO2 and iodinated contrast media in patients undergoing renovascular intervention: a prospective, randomized study. J Vasc Interv Radiol, 2005, 16:57-65.
  • 5Heye S, Maleux G, Marchal GJ. Upper-extremity venography: CO2 versus iodinated contrast material. Radiology, 2006, 241: 291-297.
  • 6Brown DB, Pappas JA, Vedantham S, et al. Gadolinium, carbon dioxide, and iodinated contrast material for planning inferior vena cava filter placement: a prospective trial. J Vasc Interv Radiol, 2003, 14: 1017-1022.
  • 7Sullivan KL, Bonn J, Shapiro M J, et al. Venography with carbon dioxide as a contrast agent. Cardiovasc Intervent Radiol, 1995, 18: 141-145.
  • 8Moresco KP, Patel N, Johnson MS, et al. Accuracy of CO2 angiography in vessel diameter assessment: a comparative study of CO2 versus iodinated contrast material in an aortoiliac flow model. J Vasc Interv Radiol, 2000, 11:437-444.
  • 9Black CM, Lang EV, Kusnick CA, et al. 1996 AUR Memorial Award. Densitometric analysis of eccentric vascular stenoses: comparison of CO2 and iodinated contrast media. Acad Radiol, 1996, 3: 985-993.
  • 10Spinosa DJ, Matsumoto AH, Angle JF, et al. Renal insufficiency: usefulness of gadodiamide-enhanced renal angiography to supplement CO2-enhanced renal angiography for diagnosis and percutaneous treatment. Radiology, 1999, 210: 663-672.

二级参考文献12

  • 1Hawkins IF. Carbon dioxide digital subtraction angiography. AJR, 1982, 139:19-24.
  • 2Lu W, Li YH, Chen Y, et al. Carbon dioxide-Digital Subtraction Angiogrphy Features of Hepatocellular Carcinoma. J Vasc Intervent Radiol, 1999, 10 (Suppl 2 part 2):300-301.
  • 33,KensSR,HawkinsIF,SabetalFW.Currentstatusofcarbondioxidedigitalsubractionangiography.RadiologicClinicalofNorthAmerican,1995;33:15
  • 44,SeegerJM,SelfS,HawkardTRS,etal.Carbondioxidegasasanarterialcontrastagent,AnnSurg,1993;217:688
  • 55,SullivanKL,BonnJ,ShapiraMJ,etal.Venographywithcarbondioxideasacontrastagent.CadiovascinterventRadiol,1995;18:141
  • 61,KatayamaH,YamagachiK,KozukaT,etal.Adersereactiontoionicandnonioniccontrastmedia.Radiology,1990;175:621
  • 72,KernsSR,HawkinsIF.Carbondioxidedigitalsubrtractionangiography:expendingapplicationandtechnicalevaluation.AJR,1995;164:735
  • 8卢伟,李彦豪,陈勇,何晓峰,潘雨亭,许小立,鲁恩杰,甘秋.CO_2-DSA的临床应用研究[J].中国医学影像学杂志,1997,5(4):228-231. 被引量:3
  • 9卢伟,李彦豪,陈勇,潘雨亭,许小立,鲁恩洁.肝海绵状血管瘤CO_2-DSA与常规DSA的比较研究[J].中国医学影像学杂志,1998,6(4):278-281. 被引量:16
  • 10卢伟,李彦豪.肝癌CO_2-DSA表现:CO_2-DSA显示动脉-门脉短路与肝内子结节的相关关系[J].中国医学影像学杂志,1999,7(1):64-65. 被引量:3

共引文献9

同被引文献2

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部