期刊文献+

大型火电机组辅助车间集中监控网络方案与配置 被引量:4

Centralized monitoring network scheme and configuration for auxiliary shop of large-scale thermal power unit
下载PDF
导出
摘要 论述了大型火电机组辅助车间的控制水平和各种监控方案及辅助车间集中监控网络系统(简称辅网)存在的问题,对制约辅助车间集中监控网络系统的几项关键技术进行了深入的分析,结合国电费县电厂一期(2×600MW超临界机组)工程,提出了基于工业以太网的大型火电机组辅助车间集中网络系统的监控方案和配置方案。 The control level of auxiliary shops of large-scale thermal power unit and various monitoring scheme were discoursed,and the problems existing in auxiliary shop centralized monitoring network system were discussed.Several key technologies restricting the auxiliary shop monitoring network system were analyzed in detail.Combining with Guodian Feixian Power Plant phase I project (2×600MW supercritical units),the monitoring plan and configuration scheme of auxiliary shop centralized monitoring network system of large-scale thermal power unit based on industrial Ethernet were provided.
出处 《华电技术》 CAS 2010年第2期46-50,共5页 HUADIAN TECHNOLOGY
关键词 集中监控 控制方式 工业以太网 辅网 配置 centralized monitor and control control mode industrial Ethernet auxiliary control network configuration
  • 相关文献

参考文献4

二级参考文献3

共引文献8

同被引文献12

引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部