期刊文献+

基于人眼光学质量的球差和离焦补偿关系研究 被引量:6

Counterbalanced Relationship Between Defocus and Spherical Aberration Based on Optical Quality Metrics of Human Eyes
下载PDF
导出
摘要 基于人眼光学质量客观评估方法,通过实测的屈光手术前后人眼波前像差数据,研究和分析了球差与离焦的补偿关系。结果表明,对于屈光手术前的近视眼患者,离焦与球差的补偿关系并不明显。对于屈光手术后的近视眼患者,离焦与球差的补偿关系明显,残余离焦可以部分补偿由于高阶像差增加引起的视功能降低。当残余离焦处于0.27D~0.74D范围内,离焦与高阶像差组合后,光学质量提高了20%以上。在屈光手术方案设计时,预留0.27D~0.74D的离焦时,可以使80%的人眼达到更好的视觉矫正效果。 Based on optical quality metrics of human eyes,the counterbalanced relationship between defocus and spherical aberration for wave-front aberration data of preoperative and postoperative myopic eyes is studied. The results show that defocus can not obviously compensate spherical aberration for preoperative patients. But the counterbalanced relationship can be distinctly observed for the postoperative patients, which reveals that the remained defocus can partially ameliorate the influence of the increased higher-order aberrations after corneal refractive surgery on visual performance. For postoperative patients, more than 20% improvement of optical quality can be achieved when the remained defocus ranges from 0.27D to 0. 74D. More than 80% of eyes can achieve better visual performance when the remained defocus ranges from 0. 3D to 0.75 for a design of vision correction.
出处 《光子学报》 EI CAS CSCD 北大核心 2010年第1期110-115,共6页 Acta Photonica Sinica
基金 国家自然科学基金(60777011) 江西省教育厅科技项目(08228)资助
关键词 视光学 光学质量标准 球差 离焦 Visual optics Metrics of optical quality Spherical aberration Defocus
  • 相关文献

参考文献6

二级参考文献66

共引文献61

同被引文献67

  • 1张源,马恩普,潘蓓,汪洋,买志彬.视频终端尺寸对儿童视疲劳的影响[J].武警医学,2022,33(12):1016-1019. 被引量:1
  • 2Ning Zhang,Xu-Bo Yang,Wen-Qiu Zhang,Long-Qian Liu,Guang-Jing Dong,Tao-Wen Chen,Meng Liao,Xuan Liao.Relationship between higher-order aberrations and myopia progression in schoolchildren: a retrospective study[J].International Journal of Ophthalmology(English edition),2013,6(3):295-299. 被引量:7
  • 3甘晓玲.弱视的定义、分类及疗效评价标准[J].中国斜视与小儿眼科杂志,1996,4(3):97-97. 被引量:1014
  • 4袁立银,郝沛明,周森林.非球面齐明透镜的设计[J].量子电子学报,2006,23(2):159-163. 被引量:5
  • 5李凤鸣.眼科全书[M].北京:人民卫生出版社,1996.2575.
  • 6向汝建,何忠武,徐宏来,等.周体板条MOPA激光光束质量主动控制[J].强激光与粒子柬,2013.25(2):358-362.
  • 7Liang J Z, William D R, Miller D T. Supernormal vision and high resolution retinal imaging through adaptive optics[J]. J Opt Soc Am A, 1997, 14(11): 2884-2892.
  • 8Thibos L N, Applegate R A, Sehwiegerling J T, et al. Standards for reporting the optical aberrations of eyes[J]. Journal of RefFaetive Surgery, 2002, 18(5): 652-660.
  • 9Niu S S, Shen J X, Liang C, et al. High-resolution retinal imaging with micro adaptive optics system[J]. Applied Optics, 2011, 50(22) : 4365-4375.
  • 10Gibson J S, Chang C C, Ellerbroe B L. Wave-front correction by use of adaptive filtering and control[J]. Applied Optics, 2000, 39(16) : 2525-2538.

引证文献6

二级引证文献8

相关作者