摘要
介绍了湖北荆门热电厂空调系统以及空调自控方面的工程设计要点;针对电厂各建筑区的特殊功能要求,进行了空调系统分区设计;根据电力设备典型消防规程要求,对电厂各电气室采用了有效的防火排烟技术措施,并选用防火保温材料和防爆型设备。该工程的设计参数和设备选型经验可供热电厂空调系统设计参考。
The project design points of Jingmen thermal power plant air-conditioning system in Hubei and air-conditioning automatic control aspects were introduced. Contrary to the specific functional requirements in all built-up areas of the plant,we design the air-conditioning system partition. According to the typical fire safety procedures requirements of electrical equipments, effective fire smoke technical measures were used in electrical rooms of the plant, and fire insulation materials and explosion-proof equipments were selected. The design parameters and equipment selection experience of the project can be consulted by other thermal power plant air-conditioning system.
出处
《制冷空调与电力机械》
2010年第1期40-43,共4页
Refrigeration Air Conditioning & Electric Power Machinery
关键词
热电厂
空调
防火排烟
自控
thermal power plant
air-conditioning
fire prevention and smoke exhausting
controls