期刊文献+

野战救护车担架支架隔振效果对比试验研究 被引量:4

Comparison Test of Vibration Isolators for Stretcher Support Frame of Field Ambulance
下载PDF
导出
摘要 目的:研究磁流变隔振装置和钢丝绳隔振装置对某型野战救护车担架支架的隔振效果。方法:对2台采用不同隔振装置的样车进行平顺性随机输入行驶试验,采用DASP软件进行信号处理并对比分析。结果:磁流变隔振装置在不同路况条件下的隔振效果均优于钢丝绳隔振装置。结论:磁流变隔振装置作为一种新型半主动控制隔振装置,适合野战救护车担架支架的二次隔振。 Objective To compare the effects of magnetorheological fluid damper and wire-rope isolator for the stretcher support frame of the field ambulance. Methoda Two ambulances equipped with the two kinds of isolators respectively went through random input running test of ride comfort, and then DASP software was applied to signal processing and contrastive analysis. Results Magnetorheological fluid damper had a better vibration isolation effect than wire-rope isolator on different kinds of roads. Conclusion As a novel semi-active controlled vibration isolator, magnetorheological fluid damper is adaptive for the two-stage vibration isolation of the stretcher support frame of the field ambulance. [Chinese Medical Equipment Journal, 2010,31 (2) : 39-42]
出处 《医疗卫生装备》 CAS 2010年第2期39-42,共4页 Chinese Medical Equipment Journal
关键词 担架支架 隔振 磁流变 钢丝绳 stretcher support frame vibration isolation magnetorheological fluid wire rope
  • 相关文献

参考文献6

  • 1朱石坚,楼京俊,何其伟,等.振动理论与隔振技术[M].北京:国防工业出版社,2006,296--297.
  • 2Ashour O, Kinder D, Giurgiutiu V ,et al. MR fluid and MR devices [C] //Simmons W C. Proc of SPIE,Vol 3 040. Washington:SPIE, 1997:174-184.
  • 3Dyke S J,Spencer Jr B F,Sain M K,et al. Modeling and control of MR dampers for seismic response reduction[J]. Smart Materials and Structrures, 1996,5 (5) : 565-575.
  • 4潘双夏,杨礼康,冯培恩.磁流变液减振控制应用的研究动态[J].汽车工程,2002,24(3):254-258. 被引量:17
  • 5段德光,王太勇,牛福,孙景工,高振海,任旭东.磁流变智能材料研究进展及在军用卫生技术车辆中的应用展望[J].医疗卫生装备,2007,28(1):34-36. 被引量:3
  • 6长春汽车研究所.GB/T4970-1996汽车平顺性随机输入行使试验方法[s].北京:中国标准出版社,1996.

二级参考文献38

  • 1方生,龚兴龙,张先舟,张培强.磁流变弹性体力学性能的测试与分析[J].中国科学技术大学学报,2004,34(4):456-463. 被引量:23
  • 2李以农,郑玲.基于磁流变减振器的汽车半主动悬架非线性控制方法[J].机械工程学报,2005,41(5):31-37. 被引量:26
  • 3[1]Tang X, Zhang X, Tao R. Enhance the Yield Shear Stress of Magnetorheological Fluids. Proceedings of the 7th International Conference on Electro-Rheological Fluids and Magneto -Rheological Suspension,July 19 23,1999:3 ~9
  • 4[2]Rabinow J. The Magnetic Fluid Clutch. AIEE Transaction.1948,67:1308 ~ 1315
  • 5[3]Gamota D R, Filisko F E. Dynamic Mechanical Studies of Electrorheological Materials: Moderate Frequencies. J. Rheology.1991,35:399 ~425
  • 6[4]Spencer Jr B F, Carlson J D, Sain M K, Yang G. On the Current Status of Magnetorheological Dampers: Seismic Protection of Full-Scale Structures. Proceedings of the American Control Conference New Mexion, June 1997:458 ~ 462
  • 7[5]Dimock Glen A, Lindler Jason E and Wereley Norman M.Bingham Biplastic Analysis of Shear Thinning and Thickening in Magnetorheological Damper. SPIE(2000)vol3985, paperno49
  • 8[6]Gavin H P, Hanson R D, Filisko F E. Electorheological Damper I: Analysis and Design. Transactins of the ASME J.Appl,Mech, 1996,63:676 ~ 682
  • 9[7]Schurter Kyle C and Roschke Paul N. Fuzzy Modeling of a Magnetorheological Damper using ANFIS. http://www. zju. edu.cn homepage: (IEEE/IEE Electronic Library)
  • 10[8]Dyke S J, Spencer Jr B F, Sain M K, Callson J D.Modeling and Control of Magnetorheological Dampers for Seimic Response. Reduction. Smart Mater. Struct. 5 (1996):565 ~575