双源CT与64层螺旋CT冠状动脉图像质量及辐射剂量的研究 被引量:3

原文传递
导出
摘要 随着64层螺旋CT的问世,冠状动脉CT血管造影(CTA)作为无创手段更广泛的应用于冠状动脉的检查,但由于其时间分辨率的限制,高心率时冠状动脉CTA的运动伪影不可避免。正因为如此,对于64层螺旋CT,通常需要酒石酸美托洛尔降低心率来提高图像质量。如果酒石酸美托洛尔效果不佳,就需要多扇区重建来提高时间分辨率。虽然多扇区重建提高了时间分辨率,但经常导致冠状动脉CTA的错层现象,并且使受检者辐射剂量明显增加。
出处 《中华放射医学与防护杂志》 CAS CSCD 北大核心 2010年第1期87-88,共2页 Chinese Journal of Radiological Medicine and Protection
  • 相关文献

参考文献5

  • 1Flohr TG, Schaller S, Stierstorfer K, et al. Multi-detector row CT systems and image reconstruction techniques. Radiology, 2005,235 (3) :756-773.
  • 2Flohr T, McCollough CH, Bruder H, et al. First performance evaluation of a dual-source CT (DSCT) system. Eur Radiol, 2006,16 (2) :256-268.
  • 3Austen WG, Edwards JE, Frye RL, et al. A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association. Circulation, 1975,51 ( 1 ) :5-40.
  • 4Menzel HG, Schibilla H, Teunen D, et al. European guidelines on quality criteria for computed tomography. Luxembourg: European Commission, 2000.
  • 5McCollough C, Primak A, Saba O, et al. Dose performance of a 64-channel dual-source CT scanner. Radiology, 2007,243 (3) : 775-784.

同被引文献25

  • 1蔡平娟,毋玉玲.冠状动脉造影术并发症的护理与对策[J].中原医刊,2005,32(7). 被引量:1
  • 2张竹花,金征宇,张抒扬,林松柏,李冬晶,孔令燕,王怡宁,宋兰,王云,赵文敏,王林辉,张晓娜,张云庆,齐冰,徐凯,梁继祥,朱海峰,牟文斌,张立仁,朱文玲,苗齐,方圻.双源CT冠状动脉成像的初步研究[J].中华放射学杂志,2007,41(9):973-976. 被引量:43
  • 3Bulla S,Pache G,Langera M,et al.Reducing the radiationdose for low-dose CT of the paranasal sinuses using itera-tive reconstruction:feasibility and image quality[J].Eur JRadiol,2011,5(10):5541-5543.
  • 4Lee SJ,Park SH,Kim AY,et al.A prospective compari-son of standard-dose CT enterography and 50% reduced-dose CT enterography with and without noise reductionfor evaluating crohn disease[J].AJR Am J Roentgenol,2011,197(1):50-57.
  • 5Renker M,Ramachandra A,Schoepf UJ,et al.Iterativeimage reconstruction techniques:applications for cardiacCT[J].J Cardiovasc Comput Tomogr,2011,5(4):225-230.
  • 6Hu XH,Ding XF,Wu RZ,et al.Radiation dose of non-en-hanced chest CT can be reduced 40 % by using iterativereconstruction in image space [J].Clin Radiol,2011,66(11):1023-1029.
  • 7May MS,Wiist W,Brand M,et al.Dose reduction in ab-dominal computed tomography:intraindividual comparisonof image quality of full-dose standard and half-dose itera-tive reconstructions with dual-source computed tomo-graphy[J].Invest Radiol?2011,46(7):465-470.
  • 8Achenbach S,Goroll T, Seltmann M,et al.Detection ofcoronary artery stenoses by low-dose,prospectively ECG-triggered,high-pitch spiral coronary CT angiography[J].J ACC Cardiovasc Imaging,2011,4(4):328-330.
  • 9Moscariello A,Richard AP,Takx U,et al.Coronary CTangiography:image quality,diagnostic accuracy,and po-tential for radiation dose reduction using a novel iterativeimage reconstruction technique-comparison with tradition-al filtered back projection [J],Eur Radiol,2011,21(10):2130-2138.
  • 10Maffei E,Martini C,Rossi A,et al.Diagnostic accuracy ofsecond-generation dual-source computed tomography cor-onary angiography with iterative reconstructions:a real-world experience[J].Radiol Med,2011,17(1):36-40.

引证文献3

二级引证文献10

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部