摘要 随着CT技术的迅速发展及应用领域的不断扩大,采用CT检查的比例也越来越高;同时CT扫描辐射剂量,以及对检查者的危害也越来越引起人们的关注。国际放射防护委员会(ICRP)主张在满足X射线诊断要求前提下应遵循所有辐射剂量保持在可合理达到的尽可能低水平的原则(ALARA)。本研究依据这个原则,用降低mAs的方法,在测量不同mAs下的CT值的均匀性、CT剂量指数、噪声水平、高对比分辨率、低对比分辨率的基础上,分析其结果,并应用到临床实践中进行统计学分析,进行初步探讨。
出处 《中华放射医学与防护杂志》 CAS CSCD 北大核心 2010年第1期92-93,共2页 Chinese Journal of Radiological Medicine and Protection
  • 相关文献

参考文献5

  • 1JJG1026-2007.医用诊断螺旋计算机断层摄影装置(CT)X射线辐射源.2007-11-02.
  • 2Slovis TL. Children,computed tomography radiation dose,and the As Low As Reasonably Achievable ( ALARA ) concept. Pediatrics, 2003, 112(4) : 971-972.
  • 3Swensen SJ, Jett JR, Sloan JA. Screening for lung cancer with low-dose spiral computed tomography. Am J Respir Crit Care Med, 2002, 165(4) : 508-513.
  • 4关文华,韩铭钧,秦培鑫,李坤伟.肺结核基本病变的多层螺旋CT低剂量扫描观察[J].中国防痨杂志,2007,29(6):549-551. 被引量:10
  • 5黄明刚,王青,郑桂芳,郭佑民,杨风林,王锟.螺旋CT胸部低剂量参数优化[J].实用放射学杂志,2008,24(7):976-979. 被引量:17

二级参考文献13

  • 1欧阳林,蔡晓娟,何平,陈晓武,曾江镇,许孟君.胸部低剂量CT扫描对不同部位结构图像质量的影响[J].放射学实践,2005,20(2):139-141. 被引量:10
  • 2亓恒涛,秦维昌,王巍,刘传亚.64层螺旋CT噪声测试及其影响因素分析[J].中华放射医学与防护杂志,2007,27(2):195-198. 被引量:17
  • 3Naidich DP, Marshall CH, Gribbin C, et al. Low - dose CT of the lungs: preliminary observations [ J ]. Radiology, 1990, 175 ( 3 ) : 729 -731.
  • 4AAPM Report No. 39. Specification and acceptance testing of computed tomography scanners [ R ]. New York: American Association of Physicsts in Medcine,1993.26- 31
  • 5[1]International Commission on Radiological Protection.1990 Recommendations of the International Commission on Radiological Protection[R].Annals of ICRP,1991,21:1-3.IRCP Publication 60
  • 6[2]Slovis TL.Children,computed tomography radiation dose,and the As Low As Reasonably Achievable (ALARA) concept[J].Pediatrics,2003,112 (4):971-972
  • 7[3]Swensen SJ,Jett JR,Sloan JA,et al.Screening for lung cancer with low-dose spiral computed tomography[J].Am J Respir Crit Care Med,2002,165(4):508-513
  • 8[4]Diederich S,Lenzen H.Radiation exposure associated with imaging of the chest:comparison of different radiographic and computed tomography techniques[J].Cancer,2000,89 (11):2457 -2460
  • 9[5]Kennedy TC,Miller Y,Prindiville S.Screening for lung cancer revised and the role of sputum cytology and fluorescence bronchoscopyin high-risk Group[J].Chest,2000,117 (4 Suppl 1):72S-79S
  • 10[6]Naidich DP,Marshall CH,Gnibbin C,et al.Low-dose CT of the lungs:preliminary observations[J].Radiotogy,1990,175(3):729-731