对某大型商业建筑采用冰蓄冷方案的经济性进行了分析。从设备初投资、年运行费用和电力消耗等方面对冰蓄冷空调与常规空调方案比较,并进行了动态经济分析。研究表明,冰蓄冷空调可减少运行费用和有效进行电力的削峰作用。为商业类建筑的冰蓄冷设计提供参考。
The economic feature of ice storage air conditioning scheme in a large-scale commercial architecture was investigatea. The first cost, running cost and power energy consumption of ice storage air conditioning system were compared with conventional air conditioning. And the dynamic economic analysis was performed. The results show that ice storage can lower annual operational cost and plays an important role in balance of electric power. It can be a reference to the ice storage system design in commercial architecture.
出处
《建筑节能》
CAS
2010年第2期23-25,共3页
BUILDING ENERGY EFFICIENCY
关键词
冰蓄冷
空调
节能
经济性分析
ice storage
air conditioning
energy conservation
economic analysis