摘要 实现了基于返波管源的太赫兹波反射式成像系统.这是一种新型的无损探伤成像方式.从样品表面或者基底反射回来的太赫兹波被焦热电探测器收集,最后经过计算机处理成像.频率为0.7THz的成像系统被用来对一系列样品进行无损检测,如硬币、徽章、模型飞机以及预埋了人工缺陷的工业样品.结果表明,很多工业材料相对于太赫兹波都是透明的,尤其是一些在航空航天技术中具有广泛应用价值的吸收微波的材料. A terahertz (THz) wave reflection imaging system based on backward wave oscillator (BWO) was presented. It is a new approach to non-destructive testing. The intensity information of the terahertz wave after being reflected from the sample surface or substrate was collected by a pyroelectric detector, and then imaged by computer. A number of samples which had potential imaging applications were tested by using 0.7 THz radiation, including coins, badges, a model airplane and some industrial samples that contained pre-built defects. The experimental results reveal that THz radiation is highly transparent to many industrial materials, especially the "microwave-absorbing" material which is widely used in aero and space technologies.
出处 《红外与毫米波学报》 SCIE EI CAS CSCD 北大核心 2010年第1期15-18,31,共5页 Journal of Infrared and Millimeter Waves
基金 国家重点基础研究发展计划"973计划"(2007CB310408) 国家自然科学基金(10390160)
关键词 无损检测 太赫兹成像 返波震荡器 反射式成像 nondestructive testing terahertz imaging backward-wave oscillator(BWO) reflection imaging
  • 相关文献

参考文献9

  • 1Hess L, Cheville R. Nondestructive evaluation of ceramic bearings using THz impulse ranging, Conference on Lasers and Electro-Optics (CLEO) [ C], 1, 729,2004.
  • 2Wihse J. History of millimeter and submillimeter waves, IEEE Trans. Microwave Theory Tech [ C ]. MTY-32 : 1119-1127,1984.
  • 3Adrian Dobroiu, Masatsugu Yamashita, Yuichi N Ohshi-ma, et al. Terahertz imaging system based on a backwardwave oscillator[ J ]. Applied Optics, 2004,43 ( 30 ) : 5637- 5646.
  • 4Chang M, Chou P, Lee H. Tomographic microwave imaging for nondestructive evaluation and object recognition of civil structures and materials [ C ]. Conference Record of The Twenty-Ninth Asilomar Conference on Signals, Systems and Computers. 1996,2 : 1061.
  • 5Sasaki A, Nagatsuma T. Reflection-type CW-millimeterwave imaging with a high-sensitivity waveguide-mounted electro-optic sensor[ J]. Jpn. J. Appl. Phys. ,2002,41:83.
  • 6Lash A, Yundev D. Submillimeter imaging with a pyroelectric TV camera [ J ]. International Journal of Infrared and Millimeter Waves, 1984 ,5 :489.
  • 7Loffler T, Kress M, Thomson M, et al. Comparative performance of terahertz emitters in amplifier-laser-based systems [ J ]. Semicond. Sci. Technol. ,2005,20 : S134.
  • 8Mei Z, Dou W. Performances of hyperbolical and spherical lens imaging systems at millimeter wavelengths [ J ]. J. of Electromagn. Waves and Appl. ,2002,16 : 1077.
  • 9Wang S, Zhang X. Terahertz tomographic imaging with a Fresnel lens[J]. Opt. Photon. News,2002,13:59.

同被引文献150

引证文献22

二级引证文献125

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部