以PLC为通信主站的Modbus控制网络的设计与实现 被引量:15

Design and Implementation of Modbus Control System Based on PLC as Master Station
下载PDF
导出
摘要 为实现以PLC为控制中心的架车式称重调簧系统,提出以PLC作为Modbus通信主站、配合多数量、多种类的通信从站的网络建立的方法,并采用S7-200 PLC、计算机和两种智能传感器,构建一个以PLC为通信主站的Modbus控制网络,对主站、从站的配置和程序设计进行了详细的说明。实践结果表明,此网络系统数据传输可靠准确,系统实时性与稳定性均能满足机车称重调簧系统应用的要求。 To realize the PLC control system of locomotive body test - rig for weighting and spring adjusting,it puts forward the method of constructing communication,which is composed of PLC Modbus master station and multiple various Modbus slave stations. At the same time, with one S7 -200 PLC, one computer and two kinds of intelligent sensors,it is built that a typical control system taking PLC as Modbus master station, and then illuminated in detail the configuration and software design master station and slavers. The practice indicates that the Modbus communication,where PLC is used as the master station, can transmit data accurately and reliably,its real -time performance and stability reaches the requirement of industrial automation.
作者 潘迪夫 习可
出处 《现代电子技术》 2010年第5期142-144,共3页 Modern Electronics Technique
关键词 MODBUS协议 PLC 通信主站 控制网络 Modbus protocol PLC master station control system
  • 相关文献

参考文献10

二级参考文献11

  • 1王仲文.精通串行通信[M].北京:电子工业出版社,2001.144-206.
  • 2[1]朱善军,翁樟等.可编程控制系统原理、应用、维护.北京:清华大学出版社,1992
  • 3魏志精,可编程控制器应用技术,1995年
  • 4周炎勋,计算机自动测量和控制系统,1992年
  • 5陈粤初,单片机应用系统设计与实践,1991年
  • 6DELTA公司,VFD-F风机水泵专用型交流马达驱动器使用手册[Z],2003
  • 7SIEMENS公司,SIMATIC S7-200可编程序控制器系统手册[Z],2000
  • 8李汉涛,杨长春,凌志浩,吴勤勤.Windows下三线制串行通信的实现方法[J].电脑技术——Hello-IT,1998(7):52-54. 被引量:6
  • 9李薇,董恒,冉蜀阳.基于VB的PLC与上位机的通讯  [J].机床电器,1999,26(3):17-19. 被引量:5
  • 10王念春,任献国,吴晨阳.啤酒厂DCS控制系统[J].自动化与仪表,1999,14(2):21-23. 被引量:5

共引文献124

同被引文献77

引证文献15

二级引证文献67

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部