期刊文献+

2种机用镍钛器械根管成形效果的对比研究 被引量:6

Comparative study on the shaping ability of canals with 2 new nickel-titanium rotary instruments
下载PDF
导出
摘要 目的:比较2种不同类型机用镍钛根管预备器械Mtwo、K3的根管成形效果。方法:选择36个离体上颌第一磨牙的近中颊侧根管,根据其弯曲度分成A(弯曲度≥20°)、B(弯曲度<20°)2组,每组再随机分成2个亚组,分别采用镍钛锉Mtwo和K3进行根管预备。预备前后,分别向根管内注入造影剂并拍摄数字X线片,利用合作研制的计算机图像分析软件生成预备前根管几何中心线并投影至预备后根管,测定根管偏移量(几何中心线偏移量)及根管弯曲度的变化。所有数据用SPSS11.0软件包进行统计学分析。结果:各组样本经t检验分析,根管弯曲度≥20°时,根管弯曲起始处的根管偏移量Mtwo组显著小于K3组(P<0.05);根管弯曲度减小量Mtwo组显著小于K3组(P<0.05)。根管弯曲度<20°时,Mtwo、K3组间根管偏移量及根管弯曲度减小量均无显著性差异(P>0.05)。结论:Mtwo、K3根管预备时均能良好维持原始根管的中心位置;预备弯曲度大于20°根管时,Mtwo可更好维持原始根管弯曲度及走向。 PURPOSE: To compare the shaping ability of two nickel -titanium rotary systems: Mtwo and K3. METHODS:Thirty-six mesio-buccal root canals of maxillary first molars were divided into two groups: group A (≥20°) and group B (〈20°),according to the angle of the canal. Then, each group was randomly divided into two subsets and prepared by Mtwo,K3, respectively. All root canals were injected with the contrast medium and digital images of all canals were recorded before and after instrumentation. The computer assistant analyze image software was used to form the geometrical central line of pre-instrumented canals. Then the central line was imaged to the post-instrumented canals. The canal transportation and the decrease of curvature were measured. All the data was analyzed with SPSS11.0 software package. RESULTS: Difference between groups was compared using t test.When the curvature of canal ≥20°,the transportation at the beginning of the curvature and the decrease of curvature of Mtwo were significantly less than those of K3 (P 〈0.05).When the curvature of canal 〈20° ,there was no significant difference between Mtwo and K3 in the transportation and decrease of curvature(P〉0.05). CONCLUSIONS: Both Mtwo and K3 systems show good preservation of the original geometry of the root canals;the Mtwo system can better preserve original curvature of canals,when the curvature of canal is larger than 20°.
出处 《上海口腔医学》 CAS CSCD 2010年第1期100-103,共4页 Shanghai Journal of Stomatology
关键词 机用镍钛锉 根管成形 根管偏移 根管弯曲度 Nickel-titanium rotary instruments Root canal shaping Root canal transportation Root canal curvature
  • 相关文献

参考文献11

  • 1韦曦,张顺彬.镍钛机动根管预备器械对根管弯曲度的影响[J].上海口腔医学,2001,10(4):333-335. 被引量:14
  • 2徐琼,范兵,樊明文,边专.ProTaper预备弯曲根管的临床评价[J].中华口腔医学杂志,2004,39(2):136-138. 被引量:69
  • 3Calberson F, Deroose C, Hommez G, et al. Shaping ability of GT^TM Rotary Files in simulated resin root canals[J]. Int Endod J, 2002, 35 (7):607-614.
  • 4Plotino G, Grande NM, Sorci E, et al. A comparison of cyclic fatigue between used and new Mtwo Ni-Ti rotary instruments [J]. Int Endod J,2006,39(9):716-723.
  • 5Dina A1-Sudani, MsEdu, Saad Al-Shahrani.A Comparison of the Canal Centering Ability of ProFile,K3, and RaCe Nickel Titanium Rotary Systems[J].J Endod,2006,32 (12): 1198-1201.
  • 6Tasdemir T, Aydemir H, Inan U, et al. Canal preparation with Hero 642 rotary Ni-Ti instruments compared with stainless steel hand K-file assessed using computed tomography [J].Int Endod J, 2005,38 (6):402-408.
  • 7Schafer E, Erler M, Dammaschke T. Comparative study on the shaping ability and cleaning efficiency of rotary Mtwo instruments. Partl.Shaping ability in simulated curved canals [J].Int Endod J, 2006,39 ( 3 ): 196-202.
  • 8Ayar LR, Love RM. Shaping ability of ProFile and K3 rotary Ni- Ti instruments when used in a variable tip sequence in simulated curved root eanals[J].Int Endod J,2004,37(9):593 - 601.
  • 9罗红霞,张岚,谭红,黄定明.可变锥度联合标准锥度的镍钛器械预备“S”形树脂根管的成形效果[J].实用口腔医学杂志,2007,23(6):836-839. 被引量:7
  • 10林正梅,凌均棨,高燕,秦伟.两种镍钛机动预备器械根管清理效果的电镜观察[J].中山大学学报(医学科学版),2005,26(6):707-710. 被引量:15

二级参考文献31

  • 1[1]Weine F, Kelly R, Lio P. The effect of preparation procedures on the original canal shape and on apical foramen shape [J]. J Endod, 1975, 1: 255-262.
  • 2[2]Esposito PT, Cunningham CJ. A comparison of canal preparation with nickel-titanium and stainless steel instruments [J].J Endod, 1995, 21(3): 173-176.
  • 3[3]Pruett JP, Clement DJ, Carnes DJ. Cyclic fatigue testing of nickel-titanium endodontic instruments [J]. J Endod, 1997, 23(2): 77-85.
  • 4[4]Southard DW, Oswald RJ, Natkin E. Instrumentation of curved molar root canals with the Roane technique [J]. J Endod, 1987, 13(10): 479-489.
  • 5[5]Baumgartner JC, Cuenin PR. Efficacy of several concentrations of sodium hypochlorite for root canal irrigation [J]. J Endod, 1992, 18(12): 605-612.
  • 6[6]Cheung GSP, Stock CJR. In vitro cleaning ability of root canal irrigants with and without endosonics [J]. Int Endo J, 1993, 26: 334-343.
  • 7[7]Thompson SA, Dummer PMH. Shaping ability of Lightspeed rotary nickel-titanium instruments in simulated root canals:Part 1 [J].J Endod, 1997, 23(11): 698-702.
  • 8Schafer R, Zapker K. A comparative scanning electron microscopic investigation of the efficacy of manual and automated instrumentation of root canals [J]. J Endod,2000, 26(11):660-4.
  • 9Ferraz CC, Zaia AA, Teixeira FB. In vitro assessment of the antimicrobial action and the mechanical ability of chlorhexidine gel as an endodontic irrigant[J]. J Endod,2001,27(7): 452-5.
  • 10Connell MS, Morgan LA, Beeler WJ, et al. A comparative study of smear layer removal using different salts of EDTA[J]. J Endod, 2000,26(12): 739-43.

共引文献97

同被引文献42

引证文献6

二级引证文献22

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部