摘要
应用Maslab的定量软件,以选择离子扫描方式,建立了有机氯农药多残留的GC-MS定量测定方法。经方法的线性试验、精密度试验、检测限试验,验证了有机氯农药多残留GC-MS分析方法的可行性。PCNB和pp'-DDT在0.0025~0.50ng,α-HCH、β-HCH、γ-HCH、δ-HCH、op'-DDT、pp'-DDD、pp'-DDE、HCB在0.0020~0.40ng范围内呈现良好的线性关系;方法的最低检出量:PCNB和pp'-DDT为0.0025ng,α-HCH、β-HCH、γ-HCH、δ-HCH、op'-DDT、pp'-DDD、pp'-DDE、HCB为0.0020ng.
A gas chromatographic electron ionization-mass spectrometric method(GC EIMS) was developed for determining organochlorine pesticide residues. Ten organochlorine pesticides including alpha, beta, gamma and delta isomers of hexachlorocyclohexane(HCH), pp' DDE, pp' DDT,op' DDT,pp' DDT,pentachloronitrobenzene (Quintozene, PCNB) and hexachlorobenzene(HCB) were determined respectively. Targeted pesticide analyses were separated on DB 5 capillary column. The optimum chromatographic conditions and MS parameter were determined. In test condition, each constituent in the standard mixture was separated efficiently. The retention time of each compound and its characteristic ion were determined in fullscan mode from 50 to 450 amu. The values of their mass spectrum on the total ion current(TIC) with fullscan mode agree with those of NIST and pesticide libraries. The characteristic ions were selected to quantify at m/z 181 for the isomers of HCH, m/z 284 for HCB, m/z 295 for PCNB, m/z 246 for pp' DDE, m/z 235 for pp' DDD, op' DDT and pp' DDT. The accuracy and reliability were proved respectively by linear test, precise test and recovery test. The linear ranges of PCNB and pp' DDT are 0 0025~0 50 μg/ml. The ranges of the isomers of HCH, pp' DDE, pp' DDD and op' DDT are 0 0020~0 40 μg/ml. The limits of detection are 0 0025ng for PCNB and pp' DDE, but 0 0020ng for the isomers of HCH,HCB, pp' DDE, pp' DDD and op' DDT.
出处
《卫生研究》
CAS
CSCD
北大核心
1998年第6期425-428,共4页
Journal of Hygiene Research
关键词
食品检验
有机氯农药
多组分残留分析
GC-MS分析
gas chromatography mass spectrometry(GC MS), organochlorine pesticide, multiresidue analysis