期刊文献+

Fenton试剂催化氧化法处理离子交换树脂再生废水 被引量:4

Treatment of Regeneration Wastewater of Ion - Exchange Resin with Fenton Agent
下载PDF
导出
摘要 针对离子交换树脂再生废水中的难降解有机物利用Fenton试剂进行催化氧化处理。实验结果表明:当反应条件是H2O2与FeSO4·7H2O摩尔比为5∶1、H2O2(30%)投加量为0.35mol/L(4次投加)、pH值为3.5、反应时间为2h时,废水的处理效果最佳;并采用正交实验确定了各反应因素对废水的CODcr去除效果的影响水平。 Catalyzed oxidation of regenerating wastewater of ion -exchange resin with Fenton reagent was studied in this paper. The experiments showed that the effects are the best when the mole ratio between H2O2 and FeSO4 ·7H2O is 5 : 1, H2O2 (30%) is 0. 35 mol/L, the pH is 3.5 and the reaction time is 2 hours. And we got to know how the various reaction factors affect the results of the removing of the CODcr in the wastewater through the orthogonal test.
作者 车春波
出处 《环境科学与管理》 CAS 2010年第2期79-81,共3页 Environmental Science and Management
基金 黑龙江省自然科学基金项目(E200818)
关键词 离子交换树脂再生废水 FENTON试剂 催化氧化 regenerating wastewater of ion - exchange resin Fenton reagent catalyzed oxidation