利用原子吸收法测定样品中四乙基铅的含量,并对准确度、回收率进行了实验。该法测量便捷,减少了测定过程中误差,节约了时间,提高了测量的准确性。
The content of tetraethyl lead is determined by atomic absorption spectrometry. The accuracy and recovery rate is tested. The results show that the method is simple with less time and high accuracy and less error.
出处
《环境科学导刊》
2010年第2期103-104,共2页
Environmental Science Survey
关键词
原子吸收
四乙基铅
测定
atomic absorption spectrometry
tetraethyl lead