摘要 在钢结构抗火研究中通常基于标准温升曲线分析钢构件的火灾响应特性,采用更接近实际火灾场景的BFD自然温升曲线,运用有限元分析软件ANSYS研究了不同火灾温升速率对某防火保护简支钢梁耐火时间的影响,并与经验公式法进行比较。结果表明:有限元分析结果与经验公式法的计算结果基本一致;不同温升速率会导致钢梁温度场变化的差异性,进而影响钢梁的耐火时间;在快速温升时,荷载大小对钢梁耐火时间的影响较大;当荷载较大时,钢梁耐火温度降低,快速温升下钢梁耐火时间较短。 The fire response characteristics of steel structure is usually studied based on the standard temperature rise curve. The BFD natural temperature rise curve which is closer to the real fire scenario is used in this paper. The effect of various tem- perature rise rate on fire resistance of a simply supported steel beam with fire coating was studied via the finite element analysis software ANSYS, and compared with the empirical formula method. The results indicate that finite element analysis are nearly the same with calculation of empirical formula; Different rates of temperature rise would result in different beam temperature distribution, which affecting the fire resistance period of the steel bearn; For the rapid temperature rise, the magnitude of load deeply affects fire resistance period of steel beam. Under higher load conditions, the limit temperature of steel beam is lower, and the fire resistance period is shorter with rapid temperature rise.
出处 《火灾科学》 CAS CSCD 2010年第1期38-44,共7页 Fire Safety Science
基金 国家自然科学基金项目资助(资助号50676089)
关键词 火灾温升速率 钢梁耐火时间 防火涂料 有限元分析 Temperature rise rate Fire resistance period of steel beam Fire coating Finite element analysis
  • 相关文献

参考文献9

  • 1Tomecek D V,Milke J A. A study of the effect of partial loss of protection on the fire resistance of steel columns[J]. Fire Technology, 1993,29(1) :4-21.
  • 2Kang Y, Ha djisOphOcleous G V, Khoo H A. The effect of partial fire protection loss on the fire resistance reduction of steel beams[A]. In: Fourth international workshop Structures in fire [C], Aveiro. Portugal. 2006,63-74.
  • 3王卫永,李国强,王培军.火灾下防火涂料破损后约束柱的稳定承载力[J].力学季刊,2008,29(1):120-126. 被引量:12
  • 4周煜琴,姚斌,胡军,高兵.不均匀防火涂层对火灾条件下某简支钢梁温升和变形特性的影响[J].火灾科学,2008,17(4):238-243. 被引量:4
  • 5杨秀萍,姚斌,门玉涛.不同升温条件下钢梁火灾行为的有限元分析[J].火灾科学,2007,16(3):157-161. 被引量:7
  • 6胡军,姚斌.简支H型钢梁火灾响应特性分析.2009年中国工程热物理学会年会.
  • 7Barnett CR. BFD curve: a new empirical model for fire compartment temperatures[J]. Fire Safety J, 2002, 37:437-463.
  • 8SFPE. The SFPE handbook of fire protection engineering. Society of Fire Protection Engineers[M], Quincy, MA, USA, 1988.
  • 9建筑钢结构防火技术规范.Technical code for fire safety of steel structure in buildings[J]. (CECS200:2006).

二级参考文献21

共引文献20

同被引文献68

引证文献10

二级引证文献20

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部