期刊文献+

槽式孔板低压湿气计量修正模型 被引量:3

Metering Correlation of Slotted Orifice for Low-pressure Wet Gas Flow
下载PDF
导出
摘要 槽式孔板用于湿气计量时,由于气相中夹杂少量液体,差压值会发生显著偏高(即“虚高”),需要建立修正模型对“虚高”进行修正。该文对孔径比为0.5的槽式孔板进行了以空气一水为介质的湿气实验研究,分析了“虚高”与Lockhart—Martinelli参数、气体富劳德数、气液密度比之间的关系,提出了一个新的槽式孔板低压湿气计量修正模型。结果表明,在表压为0.25~0.35MPa、Lockhart—Martinelli参数为0.02~0.6、气体富劳德数为0.5—2.7的测试范围内,该修正模型能够很好地预测实际“虚高”,对由于液相存在而引入的气相流量误差进行修正后,气相流量相对误差在97%的置信度下小于±4%,明显优于其他槽式孔板湿气计量修正模型,可以满足生产计量的精度要求。 A slotted orifice in wet gas metering is required to find out a correlation to correct the liquid-induced over-reading. The wet gas response of the horizontally installed slotted orifice with 0.50 beta ratio is experimentally studied. After studying the relationship between the over-reading and Lockhart-Martinelli parameter, gas Froude number, the gas to liquid density ratio, a novel metering correlation for low-pressure wet gas flow is given. The results show that the new correlation corrects the liquid induced gas flow rate prediction error of the wet gas flow to ±4% at a 97% confidence level, with the conditions of pressure from 0.25 MPa to 0.35 MPa, Lockhart-Martinelli parameter from 0.02 to 0.6, and the gas Froude number from 0.5 to 2.7, which is distinctly more precise than other correlations of the slotted orifice.
出处 《南京理工大学学报》 EI CAS CSCD 北大核心 2010年第1期91-95,共5页 Journal of Nanjing University of Science and Technology
基金 国家自然科学基金(60672003)
关键词 湿气 槽式孔板 修正模型 气体富劳德数 气液密度比 wet gas slotted orifice metering correlation gas Froude Number gas to liquid density
  • 相关文献

参考文献11

  • 1耿艳峰,冯叔初,郑金吾,关丹庆,吕勇杰.凝析天然气计量技术[J].自动化仪表,2005,26(8):1-3. 被引量:15
  • 2Mehdizadeh P. Wet gas metering: Trends in applications and technical developments[A]. SPE 77351 [ C]. San Antonio, Texas, USA: Society of Petroleum Engineers Inc, 2002.
  • 3Murdock J W. Two-phase flow measurements with orifices[J]. Basic Engineer,1962, 84(4) :419 -433.
  • 4方立德,张涛.Performance of a Horizontally Mounted Venturi in Low-pressure Wet Gas Flow[J].Chinese Journal of Chemical Engineering,2008,16(2):320-324. 被引量:9
  • 5De Leeuw R. Liquid correction of Venturi meter readings in wet gas flow [ R ]. North sea workshop, Paper 21, 1997.
  • 6Steven R. Wet gas metering with a horizontally mounted Venturi meter [ J ]. Flow measurement and Instrumentation, 2002(12) : 361 - 372.
  • 7Morrison G L, Hall K R. Comparison of orifice and slotted plate flowmeters [ J ]. Flow Measurement and Instrumentation, 1994, 5 (2) : 71 - 77.
  • 8Morrison G L, Terracina D, Brewer C, et al. Response of a slotted orifice flow meter to an air/water mixture[J]. Flow Measurement and Instrumentation, 2001, 12(3) : 175 -180.
  • 9Geng Y F, Feng S C. Study on a new type of sensor for wet gas meter[ A]. The 4th International Symposium on Measurement Techniques for Muhiphase Flows [ C ]. Beijing: International Academic Publishers, 2004:536 - 541.
  • 10Geng Y F, Zheng J W, Shi T M. Study on the metering characteristics of slotted orifice for wet gas flow [ J ]. Flow Measurement and Instrumentation, 2006 ( 17 ) : 123 - 128.

二级参考文献51

共引文献24

同被引文献19

引证文献3

二级引证文献10