摘要 自2004年2月~2009年5月,笔者共收治钢板,螺钉取出困难34例,其中普通钢板26块,螺钉64枚;锁定钢板8块,螺钉13枚,均顺利取出。
出处 《中国骨与关节损伤杂志》 2010年第3期278-279,共2页 Chinese Journal of Bone and Joint Injury
  • 相关文献

参考文献3

二级参考文献10

  • 1刘璠,唐亮,茹江英,张驰.微创内固定系统治疗膝关节周围骨折[J].中华创伤骨科杂志,2006,8(10):949-953. 被引量:13
  • 2荣国威.骨科内固定[M].北京:人民卫生出版社,1995.315-320.
  • 3Georgiadis GM, Gove NK, Smith AD, et al. Removal of the Less Invasive Stabilization System. J Orthop Trauma, 2004, 18: 562-564.
  • 4Fankhauser F, Gruber G, Schippinger G, et al. Minimal-invasive treatment of distal femoral fractures with the LISS (less invasive sta- bilization system). Acta Orthop Scand, 2004, 75: 56-60.
  • 5Wong MK, Leung F, Chow SP. Treatment of distal femoral fractures in the elderly using a less-invasive plating technique. Int Orthop, 2005, 29: 117-120.
  • 6Smith WR, Ziran BH, Anglcn JO, et al. Locking plates: tips and tricks. J Bone Joint Surg(Am), 2007, 89: 2298-2307.
  • 7王亦璁.骨与关节损伤(第3版)[M].北京:人民卫生出版社,2001.1139-1147.
  • 8孙庆寿,李承球,过邦辅,等.骨科正误.北京:人民卫生出版社,1996.494-495.
  • 9张建政,刘智,刘树清.微创内固定系统技术治疗膝关节周围骨折的并发症[J].中华创伤骨科杂志,2008,10(8):782-784. 被引量:2
  • 10陈志伸,郭延杰,练克俭,郭林新,解放军第.四肢内固定取出困难12例处理与预防[J].骨与关节损伤杂志,2002,17(2):96-96. 被引量:4

共引文献15

同被引文献36

  • 1王书军,黄淦堂,彭旭光,朱洪飞,谢平,肖裕春.钢板螺钉内固定术后取出困难之对策[J].中国骨与关节损伤杂志,2007,22(8):699-701. 被引量:13
  • 2雷晓晶.钢板螺钉取出困难应对策略[J].中华创伤骨科杂志,2007,9(9):891-892. 被引量:9
  • 3Maehsra T,Moritani S,Ikuma H. Difficulties in removal of the titanium locking plate in Japan[J].{H}Injury,2013,(08):1117-1121.
  • 4Bae JH,Oh JK,Oh CW. Technical difficulties of removal of locking screw after locking compression plating[J].{H}Archives of Orthopaedic and Traumatic Surgery,2009,(01):91-95.
  • 5Georgiadis GM, Gore NK, Smith AD, et al. Removal of the Less Invasive Stabilization System [ J ]. J Orthop Trauma,2004,18 (8) : 562-564.
  • 6Peter JL, Jehson. AO principles of fracture management [ J ]. The Journal of the American Medical Association, 2008,300 (20) :2432-2433.
  • 7Christensen FB, DalsLra M. Sejlin F,et al. Titaninium- alloy enhances bone-pedicle screw fixation:mechanical and histomorphometerical results of titanium-alloy ver- sus stainless steel [ J ]. Eur spine J, 2000,9 ( 2 ) : 97- 103.
  • 8Houle JB, Tabrizi P, Giachino AA, et al. Refracture rate after plate removal from the radial metaphsis[ J]. Can J Surg ,2002,45 ( 1 ) :53-56.
  • 9Cole PA,Zlowodzki M,Kregor PJ. Treatment of proximal tibia frac- tures using the less invasive stabilization system:surgical experi- ence and early clinical results in 77 fractures [J]. J Orthop Trauma, 2004,18(8) : 528-535.
  • 10Georgiadis GM, Cove NK, Smith AD, et al. Removal of the less inva- sive stabilization system[J]. J Orthop Trauma,2004,18(8) :562-564.