摘要
叙述了华能珞璜发电有限责任公司2号汽轮机关闭加热器空气门试验过程及方法,并对试验结果进行了分析。根据分析结果表明,汽轮机在正常运行中,加热器汽侧空气排放方式,可由原来连续排放,改为间断式排放。
The experimental process and method for closed exhaust valve of heat exchanger of Huaneng Luohuang Power Limited Company turbine set is described,and also the experimental results are analyzed. The results of the analysis show that when steam turbine is in normal operation,heaters steam-side air exhaust original mode continuous exhaust can be replaced by intermittent exhaust.
出处
《电站系统工程》
北大核心
2010年第1期52-52,55,共2页
Power System Engineering
关键词
汽轮机
加热器
空气门
经济性
steam turbine
heaters
exhaust valve
economy