摘要 本文结合近年来北京地区地下空间开发利用中,诱发环境影响一典型工程实例,分析了场区岩土工程条件、地下支护结构设计方案、地下支护结构施工工艺、环境变形观测资料以及出现的异常现象等。找出了地下空间开挖诱发相邻建筑物裂缝的两个主要原因为:①北京顺义地区地层土灵敏度较高,施工扰动可使其抗剪强度指标降低,锚杆施工时支护结构地下连续墙发生的水平位移较大;②锚杆施工工艺不当,钻孔中出现了大量泥水喷涌现象,导致相邻建筑物地基基础倾斜过大。提出了锚杆施工时应采取降低地基土扰动的套管跟进、间隔跳打和二次压浆等相应技术措施。工程及时应用后建筑物沉降变形得到了有效控制。 Based on typical cases of the project induced environmen.tal impact in recent years in underground space development and utilization of Beijing, an analysis is carried out on field geotechnical conditions, the under- ground supporting structure design, underground supporting structure construction technology, environmental deformation data, as well as abnormal phenomena, and so on. Two main reasons of underground space excavation - induced cracks in adjacent buildings have been found: (1) Beijing ShunYi area has high soil sensitivity, the construction disturbance can reduce the shear strength index during the bolt construction, on the slurry - wall a greater level of dis- placement took place ; (2) the bolt construction technique is improper, there have been a large number of mud and water spewing in bore hole, leading to adjacent buildings foundation incline too much. This paper puts forward that in bolt construction measures should be taken to reduce soil disturbance, such as the casing following up, interval hop and beat, the second pressure grouting and other technical measures. After applications of the measures timely the building settlements have been effectively controlled.
出处 《地下空间与工程学报》 CSCD 北大核心 2009年第A02期1731-1735,1750,共6页 Chinese Journal of Underground Space and Engineering
基金 国家"十一五"科技支撑计划:城市地下空间建设工程化技术开发(2006BAJ27B05)
关键词 地下空间 环境影响 锚杆施工 变形控制 underground space environmental impact bolt construction deformation monitoring
  • 相关文献

参考文献4

  • 1中华人民共和国行业标准.建筑基坑支护技术规程(JCJ120-99)[S].中国建筑工业出版社,1999.
  • 2赵延林,高全臣,衡朝阳.基坑开挖对近邻建筑物沉降影响的数值模拟[J].黑龙江科技学院学报,2005,15(2):106-110. 被引量:13
  • 3顺义区医院门诊病房楼、住院楼、新建工程基坑鉴定报告(BETC-JC-2006-38)[R].国家建筑工程质量监督检验中心.
  • 4北京市顺义区医院住院楼、门诊楼、新建工程基坑施工支护评价[R].中国建筑科学研究院地基基础研究所.

二级参考文献3

共引文献12

同被引文献13

引证文献1

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部