摘要 报道了一种微型化铷原子钟,它采用一种新型陶瓷填充微波腔来减小物理部分体积,其铷光谱灯采用升压电路以实现快速点亮,整机电子线路采用低电压技术,在国内首次对这类铷钟实现12 V直流供电,并且首次对这类铷钟加入与外秒同步的功能。该铷原子钟体积为190 mL,开机3 min后可实现锁定,锁定后频率稳定度为1.5×10-11/τ(1/2)(τ:1~1 000 s),稳态功耗为5.5 W。 An ultra-miniature Rb atomic clock is reported in this paper. For this Rb atomic clock, the microwave cavity is filled with a new type of ceramic material to reduce the physics package, the Rb spectrum lamp can lighten instantly with the aid of a voltage step-up circuit. Besides, it is the first time in China for this kind of clocks that the low voltage technique is applied to the circuits to realize 12 V (DC) supply and the output signal of this ultra-miniature Rb atomic clock can be synchronized with outside 1 PPS (1 pulse per second) signal. The volume of this Rb atomic clock is 190 mL and it can be locked in 3 minutes after starting. The frequency stability of this clock is 1.5× 10^-11/√τ (τ : 1 - 1 000 s), the power dissipation is 5.5 W for stable status.
出处 《时间频率学报》 CSCD 2009年第2期92-95,共4页 Journal of Time and Frequency
基金 电子科技集团第十研究所产业基金资助项目(M08001)
关键词 铷原子钟 陶瓷微波腔 微型化 低功耗 Rb atomic clock ceramic microwave cavity ultra-miniaturization low power
  • 相关文献

参考文献4

  • 1曹远洪.小型化铷原子钟研究[D].武汉:中国科学院武汉物理与数学研究所,2007.
  • 2曹远洪,蒲晓华,刘勇军,杜伦宇,杨林.铷原子频标小型化发展现状[J].时间频率学报,2007,30(2):132-137. 被引量:4
  • 3楼仁海.工程电磁场[M].北京:国防工业出版社,1983:262-267.
  • 4VANIER J, CLAUDE A. The Quantum Physics of Atomic Frequency Standard[J]. Adam Hilger, Bristol and Philadelphia, 1990, 249(4969): 685-688.

二级参考文献14

  • 1EMMER W,WATTS E.Atomic Frequency Standards for the GPS IIF Satellites//29th Annual Precise Time and Time Interval (PTTI) Meeting.California:United States Naval Observatory,1997.
  • 2KWON T M,WILLIAMS H E.Cavity Resonator for Atomic Frequency Standard:United Stated,4495478[P].1983-02-06.
  • 3SCHWEDA H S,BUSCAUS G,ROCHAT P.Atomic Frequency Standard:United Stated,5387881[P].1993-03-09.
  • 4MEI Gang-hua,ZHONG Da,AN Shao-feng,et al.Miniaturized Microwave Cavity for Atomic Frequency Standard:United Stated,6225870[P].1999-10-25.
  • 5JIN Quan-deng.Subminiature Microwave Cavity for Atomic Frequency Standards[C]//IEEE International Frequency Control Symposium and PDA Exhibition,2001:85-88.
  • 6BUSCA G,JOHNSON L.Passive Frequency Standard:United Stated,4947137[P].1989-02-28.
  • 7CHANTRY P J,WEINERT R W,TALLISA S H,et al.Miniaturized Atomic Frequency Standard:United Stated,5192921[P].1991-11-21.
  • 8SKOCZEN G.Resonator Package for Atomic Frequency Standard:United Stated,5627497[P].1996-02-16.
  • 9ENGLISH T C.Evanescent-field Interrogator for Atomic Frequency Standards:United Stated,5517157[P].1993-04-27.
  • 10KOYAMA Y,MATSUURA H,ATSUMI K,et al.An Ultra-Miniature Rubidium Frequency Standard[C]//IEEE/EIA International Frequency Control Symposium and Exhibition,2000:694-699.

共引文献3

同被引文献9

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部