摘要 采用超声辅助电凝聚技术处理含磷废水,研究该技术的可行性及其特点.通过对比实验表明,在相同实验条件下,超声辅助电凝聚除磷效率比磁力搅拌电凝聚除磷效率高18.40%.进行L16(44)四水平四因素正交优化试验,结果表明,超声-电凝聚除磷的影响因素主次关系依次为pH、磷初始浓度、电混凝时间、电极间距.在最优组合工艺条件下,即电极间距为2cm,pH为7,电混凝时间为3min,磷初始浓度为10mg·L-1,磷的去除率达到99.60%.初步分析了超声-电凝聚除磷的机理以及超声在电凝聚除磷过程中的作用.动力学分析表明,超声-电凝聚除磷符合零级反应动力学规律.能耗估算表明,超声-电凝聚技术除磷的单位磷能耗明显低于磁力搅拌电凝聚除磷的单位磷能耗. Phosphorus-containing wastewater was treated by an ultrasound-assisted electro-coagulation process.The ultrasound-assisted process improved the phosphorus removal efficiency significantly,up to 18.40% higher compared with simply stirring under the same conditions.An L16(44) orthogonal test was carried out to determine the details of the process.The four major factors were found to influence the phosphorus removal efficiency in the order of pH,initial concentration of phosphorus,electro-coagulation time,inter electrode distance.Under the optimized conditions 2 cm of inter electrode distance,pH=9,3 minutes of electro-coagulation time,and 10 mg·L^ -1 initial phosphorus concentration up to 99.60% phosphorus removal was achieved.The ultrasound-assisted electro-coagulation process was found to fit zero-order kinetics,and energy consumption per unit phosphorus removed was significantly lower than the stirring process.The effect of ultrasound on the process is also discussed.
出处 《环境科学学报》 CAS CSCD 北大核心 2010年第3期519-523,共5页 Acta Scientiae Circumstantiae
基金 "十一五"国家科技支撑计划(No2006BAD04A12)~~
关键词 电凝聚 超声 除磷 动力学分析 electro-coagulation ultrasound removal of phosphor kinetic analysis
  • 相关文献

参考文献3

二级参考文献6

  • 1冯爽 孔海南 褚春凤.关于电絮凝除磷工艺的电解时间和电压与除磷效率的关系研究[A]..中国化学会第六届水处理化学大会论文集[C].南京,2002..
  • 2Nihal Bektas,Hilal Akbulut, Hatice Inan,et al.Removal of phosphate from aqueous solutions by electro-coagulation[J].Journal of Hazardous Materials,2004,101-105.
  • 3中国标准出版社第二编辑室.中国环境保护标准汇编水质分析方法[S].北京:中国标准出版社,..
  • 4张唯,杨启峰,刘秀芝.生物除磷机理及试验研究[J].环境工程,1999,17(5):17-18. 被引量:31
  • 5顾小红,黄种买,虞启义.污水除磷技术的现状及发展趋势[J].中国资源综合利用,2002,20(5):26-28. 被引量:5
  • 6冯爽,孔海南,褚春凤,郭能吉.电絮凝法去除二级处理出水中的磷[J].中国给水排水,2003,19(1):52-54. 被引量:20

共引文献37

同被引文献79

引证文献7

二级引证文献13

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部