摘要 阐述了将激光扫描显示技术应用于医疗辅助显示领域的优势.针对临床诊疗中穿刺操作因病患静脉血管不清晰而带来的困难,设计并搭建一种基于双波长激光扫描的皮下静脉血管显示装置,介绍了该装置的基本原理、系统构成、关键器件及工作方式.分别从静态和动态两方面对静脉血管与周围组织对红外光的吸收差异进行测量,结果表明,静脉与其他组织对红外光的吸收率差一般不超过10%.设计散射光收集装置,解决了到达探测面光能量过低以及扫描光点运动带来的干扰问题.所搭建的装置能够将红外光吸收较明显的静脉血管用可见激光显示在体表原有位置,达到了预期的实验效果. Advantages of laser scanning display in the field of medical treatment aided display were introduced.Subcutaneous vein display equipment based on dual-wavelength laser scanning was designed and constructed due to the inconvenience of centesis in the clinic treat.The basic principle,structure,key components and working modes of the equipment were given.The infrared absorbance difference between vein and other adjacent tissue was measured statically and dynamically.Results showed that the difference of infrared absorbency was below 10%.A unit for collecting scattered light was built.Then the problems of comparatively low light energy arriving at the detector and the interference due to the movement of scanning light spot were overcomed.The subcutaneous vein having obvious infrared absorption can be displayed on the correct position by the equipment.The expectant result was achieved.
作者 张帆 刘向东
出处 《浙江大学学报(工学版)》 EI CAS CSCD 北大核心 2010年第2期294-299,共6页 Journal of Zhejiang University:Engineering Science
关键词 双波长 激光扫描显示 静脉显示 红外探测 散射光收集 dual-wavelength laser scanning display vein display infrared detection scattered light collection
  • 相关文献

参考文献8

  • 1公丕欣,张静,宋明娇.疑难浅静脉穿刺技术与方法研究进展[J].现代护理,2004,10(11):1054-1055. 被引量:13
  • 2ZEMAN H D, LOVHOIDEN G, VRANCKEN C. Prototype vein contrast enhancer[C]//Advanced Biomedical and Clinical Diagnostic Systems Ⅱ, Proceedings of SPIE.Bellingham, WA, SHE, 2004:39-49.
  • 3ZEMAN H D, LOVHOIDEN G, VRANCKEN C, et al. Prototype vein contrast enhancer[J]. Optical Engineering, 2005, 44(8) : 1 - 9.
  • 4ZEMAN H D, LOVHOIDEN G. Enhancing the contrast of subcutaneous veins[C]//Biomedical Diagnostic, Guidance, and Surgical-Assist Systems, Proceedings of SPIE. California: SPIE, 1999:219-230.
  • 5VILLASENOR C, SANCHEZ F J, GARAY M E. Contrast enhancement of mid and far infrated images of subcutaneous veins [J]. Infrared Physics and Technology, 2008, 51: 221-228.
  • 6SPRAGUE R, MOTAGUE T, BROWN D. Bi-axial magnetic drive for scanned beam display mirrors[C]//MOEMS Display and Imaging Systems Ⅲ, Proceedings of SPIE. Bellingham, WA: SPIE, 2000:1-13.
  • 7苗永平,刘永智.二维激光扫描规律研究[J].应用光学,2005,26(2):27-30. 被引量:6
  • 8ZEMAN H D, LOVHOIDEN G, DESHMUKH H. Optimization of subcutaneous vein contrast enhancement[C]//Biomedieal Diagnostic, Guidance, and Surgical-Assist Systems Ⅱ, Proceedings of SPIE. California: SHE, 2000: 50-57.

二级参考文献24

  • 1俞文敏 尹跃军.手背浅静脉显示仪的研制及临床应用[J].中华护理杂志,1997,32(7):382-382.
  • 2徐界平.声光器件的原理、设计和应用[M].北京:国防工业出版社,1982..
  • 3D Maydan. Acoustooptical Pulse Modulators [J]. IEEE J Quantum Electronics, 1970 ,QE-6 : 15 -24.
  • 4J Xu, R Stroud. Modulators in acousto-optic devices: Principles, Design, and Applications [M ].NewYork:Wiley & SonsIne, 1992.
  • 5Redmond P Aylward Denver. The advances & technologies of galvanometer-based optical scanners[J].SPIE, 1999,3787:158-164.
  • 6Yong Honn Kim,Hang Woo Lee,Seung Nam Cha.Full color laser projection display using Kr-Ar (White Laser) beam scanning technology[J]. SPIE,1997,3131:2-10.
  • 7张荣灿.介绍一种毛细血管输液法[J].山西护理杂志,1999,13(4):181-181.
  • 8陈翠华.静脉穿刺进针角度的探讨[J].中华护理杂志,1997,32(6):356-357. 被引量:178
  • 9冯建兰,方小平,阮玉.微机在激光扫描显示中的应用[J].电脑学习,1998(1):18-20. 被引量:1
  • 10王家香.逆向静脉穿刺在输液中的应用[J].实用护理杂志,1998,14(4):203-204. 被引量:33

共引文献17

同被引文献35

  • 1张永良,李忠海.图像处理算法的效果评价标准分析[J].武汉理工大学学报(交通科学与工程版),2006,30(2):332-335. 被引量:9
  • 2张晋阳,孙懋珩.红外静脉辅助定位系统设计[J].电子测量技术,2007,30(3):140-143. 被引量:4
  • 3王宣银,潘锋,向桂山,梁冬泰.基于Snake模型的特定人脸三维重建方法[J].机械工程学报,2007,43(7):168-173. 被引量:8
  • 4王燕青.可视化静脉穿刺仪:中国.202055551Y[P].2008-05-07.
  • 5浙江大学.双色激光扫描式医用静脉显示装置:中国.101156778A[P].2008-04-09.
  • 6武汉呵尔医疗科技发展有限公司.一种表层血管显示方法和仪器:中国,102415886A[P].2012-04-18.
  • 7Zeman H D, Lovhoiden G, Deshmukh H. Optimization of subcuta- neous vein contrast enhancement[C]//Biomedical Diagnostic, Guid- ance, and Surgical-Assist Systems Ⅱ, Proceedings of SPIE. Califor- nia: SPIE, 2000 : 50-57.
  • 8魏学业,于冬.LED应用技术[M].北京:机械工业出版社,2011.
  • 9新势力电光.新光源投影市场[EB/OL].(2011-11-09)[2013-02-01].http://www.newopto.com/13080-819/26377_25470.html.
  • 10Frank C. Venoseope Apparatus:US, 6923762B I[P]. 2005-08-02.