期刊文献+

Complement of ^(99m)Tc-octreotide scintimammography to mammography in evaluating breast cancers

Complement of ^(99m)Tc-octreotide scintimammography to mammography in evaluating breast cancers
下载PDF
导出
摘要 In this paper,the 99mTc-octreotide scintimammography as a useful complementary technique of mammography was evaluated in diagnosing breast cancers.The 45 breast lesions were consecutively detected by mammography,and 99mTc-octreotide scintimammography,and both combination technique on the basis of self-examination,physical examination.Clinical diagnosis was confirmed by histopathologic analysis.Radioactivity uptake ratios for tumor vs normal breast tissues (T/NT) were calculated using regions of interest.In the breast cancer groups and the benign lesion groups,the average uptake ratios of the 99mTc-octreotide were 1.63±0.19 and 1.09±0.13,respectively,and t was 9.638 (P<0.001).Based on sensitivity,specificity,accuracy,positive predicting value,and negative predicting value,99mTc-octreotide scintimammography was 87%,79%,84%,90%,and 73%,the mammography was 65%,64%,64%,80%,and 45%,and both combination was 95%,100%,97%,100% and 92%,respectively.This showed that the 99mTc-octreotide scintimammography was more useful than mammography in the evaluating suspected breast cancers,and the combination technique can accurately discriminate lesions. In this paper, the 99mTc-octreotide scintimammography as a useful complementary technique of mammography was evaluated in diagnosing breast cancers. The 45 breast lesions were consecutively detected by mammography, and 99mTc-octreotide scintimammography, and both combination technique on the basis of self-examination, physical examination. Clinical diagnosis was confirmed by histopathologic analysis. Radioactivity uptake ratios for tumor vs normal breast tissues (T/NT) were calculated using regions of interest. In the breast cancer groups and the benign lesion groups, the average uptake ratios of the 99mTc-octreotide were 1.63±0.19 and 1.09±0.13, respectively, and t was 9.638 (P〈0.001). Based on sensitivity, specificity, accuracy, positive predicting value, and negative predicting value, 99mTc-octreotide scintimammography was 87%, 79%, 84%, 90%, and 73%, the mammography was 65%, 64%, 64%, 80%, and 45%, and both combination was 95%, 100%, 97%, 100% and 92%, respectively. This showed that the 99mTc-octreotide scintimammography was more useful than mammography in the evaluating suspected breast cancers, and the combination technique can accurately discriminate lesions.
出处 《Nuclear Science and Techniques》 SCIE CAS CSCD 2010年第1期24-28,共5页 核技术(英文)
基金 Supported by Xiamen Municipal Health Bureau (Grant No. WSK0614)
关键词 X光检查 乳腺癌 乳房 评估 像对 结合技术 病理诊断 Breast cancer diagnosis, 99mTc-octreotide scintimammograpy, Mammography
  • 相关文献

参考文献20

  • 1Yang L, Li L D, Chen Y D, et al. Parkin. Chin J Oncol,2006, 28(6): 438-440.
  • 2Mulero F, Nicolas F, Castellon M I, et al. Rev Esp Med Nucl, 2000, 19(5): 344-349.
  • 3Berg W A, Gutierrez L, NessAiver M S, et al. Radiology, 2004, 233 (3)" 830-849.
  • 4Prats E, Aisa F, Abos M D, et al. J Nucl Med, 1999, 40(2): 296-301.
  • 5Brazeau P, Vale W, Burgus R, et al. Science, 1973, 179(68): 77-79.
  • 6Epelbaum J. Prog Neurobiol, 1986, 27(1): 63-100.
  • 7Arimura A, Fishback JB. Neuroendocrinol, 1981, 33(4): 246-256.
  • 8Patel Y C, Reichlin S. Endocrinol,1978, 102(2): 523-530.
  • 9Reichlin S J, Lab Clin Med, 1987, 109(3): 320-326.
  • 10Khanna G, Bushnell D, O'Dorisio M S. Oncologist. 2008, 13(4): 382-389.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部