期刊文献+

不完全厌氧—好氧同反应器工艺处理印染废水的研究 被引量:12

Study on Biological Treatment of Dyeing Wastewater by Anaerobic Hydrolytic-Aerobic Technology in One Bioreactor
下载PDF
导出
摘要 不完全厌氧—好氧同反应器工艺是通过时段切换在同一反应器内实现印染废水处理的过程。结果表明,反应器体积为30L,水力停留时间为12h,总COD_(Cr)去除率达85%,总BOD_5达94.3%,总色度为87.5%,处理出水COD_(Cr)为140mg/L,BOD_5为8mg/L,色度为50倍,达到了国家二级排放标准。实验表明,经厌氧时间段后,BOD_5/COD_(Cr)由0.15提高至0.37,色度由400倍降至50倍,为好氧时间段的COD_(Cr)去除和总的处理效果提供了保证。 Treatment of dyeing wastewater by a novel anaerobic hydrolytic-aerobic technology in one bioreactor has been studied in the laboratory. The results showed that the total removal rates of CODCr, BOD5 and chromaticity were 85%, 94.3% and 87.5% respectively as the hydraulic retention time was 12 hours. The average concentrations of CODCr, BOD5 and chromaticity (in the final effluent) were 140mg/L, 8mg/L and 50fold respecively, which met the National Discharge Standards of wastewater. After anaerobic hydrolytic stage treating, the BOD5/CODCr ratio of waste-water increased from 0.15 to 0.37 and the chromaticity decreased from 400 to 50fold, which contributed a lot of the following aerobic stage high CODCr removal rate.
机构地区 上海交通大学
出处 《上海环境科学》 CAS CSCD 1998年第12期31-32,共2页 Shanghai Environmental Sciences
关键词 印染废水 废水生物处理 不完全厌氧 好氧 Dyeing wastewater Biological wastewater treatment Anaerobic hydrolytic Aerobic
  • 相关文献

参考文献7

二级参考文献8

  • 1沈德康,技术经济,1991年
  • 2王曙光,城市环境与城市生态,1988年,1卷,4期,33页
  • 3罗幼华,Water Treatment,1991年,6卷,2期,237页
  • 4团体著者,给水排水设计手册.6,1986年
  • 5汪凯民,环境科学,1992年,13卷,4期,62页
  • 6团体著者,纺织印染废水,1988年
  • 7宋仁元,水和废水标准检验法,1985年
  • 8周学双.染料工业三废治理的发展方向[J].化工环保,1992,12(6):333-336. 被引量:30

共引文献34

同被引文献192

引证文献12

二级引证文献117

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部