摘要
通过对平圩电厂1号、2号机两台同型号的5号低压加热器实际运行参数的对比,分析出1号机5号低压加热器运行中疏水管发生振动的根本原因及消除振动的解决方案。
The actual parameters of the same type two low-pressure heaters have been contrasted for unit 1 and unit 2 in Pingwei power plant. Finally the vibration intrinsic reason of the drain pipe for No. 5 low pressure heater of unit 1 had been analyzed and the solution of dispel vibration was put forward.
出处
《电力科学与工程》
2010年第3期49-53,共5页
Electric Power Science and Engineering