期刊文献+

在屏蔽墙外用雷姆计测量高能中子的修正因子 被引量:1

Rem-Meter Correction Factor for High Energy Neutron Outside Concrete shielding
原文传递
导出
摘要 考虑到穿过混凝土屏蔽墙后中子能谱相对变“硬”的效应和中子雷姆计的能量响应特性,计算了用10英寸直径单球雷姆计和标准A-B雷姆计在屏蔽墙外测量中能重离子反应出射高能中子剂量当量的修正因子。 For the 10 inch diam. single-sphere rem-meter and the standard A-B rem-meter placed outside the concrete shielding wall, correction factors for measuring the high energy neutron dose equivalent produced by intermediate energy heavy ion reaction have been calculated taking into account the energe response of the rem-meter and the effect that the neutron spectra become remarkably 'harder' after penetrating through a concrete shielding wall.
作者 李桂生
出处 《高能物理与核物理》 EI CSCD 北大核心 1998年第11期977-981,共5页 High Energy Physics and Nuclear Physics
关键词 雷姆计 修正因子 高能中子 剂量当量 屏蔽 rem-meter correction factor high energy neutron dose equivalent shielding
  • 相关文献

参考文献3

二级参考文献4

同被引文献5

  • 1Li Guisheng,Health Phys,1998年,75卷,4期,405页
  • 2Li Guisheng,Nucl Instr Meth,1998年,A404期,349页
  • 3Li Guisheng,Nucl Instr Meth,1997年,A394期,381页
  • 4Li Guisheng,核物理动态,1991年,8卷,3期,32页
  • 5Guo Zhiyu,Nucl Instr Meth B,1987年,29卷,500页