摘要 结合福建省福州超高压输变电局500 kV变电站通信无人值班运行管理现状,从电源、网络结构、标签命名、资源管理、机房环境、应急机制方面,对通信站无人值班实践运行经验进行探讨和总结,并对运行实践中存在的不足提出改善建议,为通信站无人值班提供更加可靠、完善的技术和管理手段,以便更加合理和科学地管理通信网,在减员增效的同时,确保通信网安全稳定运行。 Based on the current situation of unattended communication stations in 500 kV substations of Fuzhou Extra High Voltage Power Transmission Substation Bureau,this paper discusses the operational experiences of unmanned communication station from the aspects of power supply,network configuration,label naming,resources management,communication room environment as well as the emergency response mechanism.Some suggestions and recommendations for further improvement are also put forward in the paper.