期刊文献+

炭纤维底衬不锈钢气体测量源盒的研制 被引量:4

Design and Performance Test of Carbon Fiber Bottom and Stainless Steel Body Gas Cell
下载PDF
导出
摘要 描述了炭纤维底衬不锈钢气体源盒的研制和性能测试过程。在模拟计算气体源探测效率随几何形状变化的基础上,结合实际应用研制了炭纤维底衬不锈钢气体测量源盒,有效减小了源盒底部材质对气体氙同位素低能γ或X射线的吸收。对其进行性能测试表明,源盒在10pa至2.0atm压力范围内气密性良好,可用于气体样品的测量与研究。 It describes the procedure of design and performance test of one kind of gas measurement cell, the gas measurement cell with carbon fiber bottom and stainless steel body was designed on the basis of simulation optimum geometry according to the diameter of detector crystal. The cell with thin carbon fiber bottom minimizes the adsorption of X-ray and γ-ray of gas sample effectively and improves the system detectable sensitivity. The results of performance test show that the cell has good airtightness and the pressure that the cell can bear is from 10pa to 2atm. The cell is very suitable to use for gas sample measurement and research.
出处 《核电子学与探测技术》 CAS CSCD 北大核心 2010年第1期27-30,38,共5页 Nuclear Electronics & Detection Technology
关键词 气体源盒 炭纤维 峰效率 吸收 Gas cell, Carbon fiber, peak efficiency, absorption
  • 相关文献

参考文献8

  • 1P. karhu and R. Clawsor. Raclionuclide laboratories supporting the network of radionuclide stations in verification of the Comprehensive Nuclear-Test-Ban Treaty [J]. KERNTECHNIK, 2001, 66(3) : 126 - 128.
  • 2M. Matthews and J. Schulze The radionuelide monitoring system of the Comprehensive Nuclear- Test-Ban Treaty Organisation: Irom sample to product [J].KERNTECHNIK, 2001, 66 (3), 102 -112.
  • 3J.-P. Fontaine, F. Pointurier, X. Blanehard, T. Taffary. Atmospheric xenon radioactive isotope monitoring [J]. J. Environ.Radioact. , 2004, 72: 129 -135.
  • 4A. Ringbom, T. I.arson, A. Axelsson, K. Elmegren, C. Johansson. SAUNA- a system for automatic sampling, processing, and analysis of radioactive xenon[J]. Nucl. Instr. Meth., 2003, A508:542 -553.
  • 5R. B.Firestone. Table of Isotopes CD-ROM, Eighth Edition. New York: John Wiley and Sons, 1998.
  • 6F. Bronson. Validation of the accuracy of the LabSOCS software for mathematical efficiency calibration of Ge detectors for typical laboratory samples[J]. 2003, 255(1) : 137 -141.
  • 7朱文凯,陈军,熊建平,陈坤,陈益军.ISOCS系统无源效率刻度测量方法的准确性检验[J].核电子学与探测技术,2005,25(3):287-290. 被引量:33
  • 8Canberra User's Manual of Model S574 LabSOCS Calibration Software [M]. USA, 2002.

二级参考文献5

共引文献32

同被引文献21

  • 1袁肇云,魏义彬,岑韬,王志远,吴绍云.ORTEC高纯锗伽玛谱仪系统的功能与特点[J].核电子学与探测技术,2007,27(3):611-616. 被引量:7
  • 2张利兴.禁核试核查中放射性惰性气体的监测[J].核技术,2004,27(10):770-777. 被引量:23
  • 3Canberra. User’s manual of model S573 ISOCS Cali-bration Software[Z]. USA,2002.
  • 4Canberra. User,s manual of model S574 LabSOCSCalibration Software [ Z ]. US A,2002 .
  • 5R. Plenteda. A Monte Carlo Based Virtual GammaSpectroscopy Laboratory[D]. Austria: Institute of A-tomic and Subatomic Physics, 2004.
  • 6马吉增,刘立业,潘红娟,等.髙纯锗探测器无源效率刻度的方法:中国,CN101038261[P]. 2007 - 09.
  • 7Comprehensive Nuclear - Test - Ban Treaty. Text ofthe treaty and its protocol [ R]. New York, USA: [ s.n. ] ,1996.
  • 8P. karhu,R. Clawson. Radionuclide laboratories sup-porting the network of radionuclide stations in verifica-tion of the Comprehensive Nuclear - Test - Ban Treaty[Jj.KERNTECHNIK, 2001, 66(3) :126-128.
  • 9J. P. Fontaine, F. Pointurier, X. Blanchard,et al.Atmospheric xenon radioactive isotope monitoring[J]. J. Environ. Radioact.,2004, 72: 129-135.
  • 10A. Ringbomf T. Larson, A. Axelsson, et al. SAUNA-a system for automatic sampling, processing, and a-nalysis of radioactive xenon [ J ] . Nucl. Instr. Meth.A ,2003 , 508 : 542-553.

引证文献4