期刊文献+

上海世博会篷房建筑的防火设计原则 被引量:4

Fire protection design of tent house in Expo 2010 Shanghai
下载PDF
导出
摘要 篷房具有临时性及易装拆的特点,耐火性差、消防设施欠缺、火灾隐患多。篷房外应设置避难场地;安全出口应结构坚固,疏散通道应谨慎使用坡道;应注重照明设备、电气线路的耐火性能并设防火保护设备。篷房灭火设施轻便易操作。采用膜材料作为篷房的围护体,当膜熔融性好且无滴落物时有利于排烟和人员疏散。 Tent house is easy to build or remove and has the features of bad fire resistant,lack of fire fight equipment and more hidden fire danger.The refuge space is needed and the exit of tent house must be solid.The ramp must be used carefully.More attention should be paid on fire resistant of illuminations and electrical wire and fire protection equipment should be set on them.The fire extinguishing equipment in tent house is portable and easy to operate.It's helpful to smoke exhausting and evacuation when the membrane,as the cladding of tent house,has good meltbility and no dropping.
作者 赵华亮
机构地区 上海市消防总队
出处 《消防科学与技术》 CAS 北大核心 2010年第3期206-208,213,共4页 Fire Science and Technology
关键词 上海世博会 篷房 防火设计 火灾报警 膜材料 Expo 2010 Shanghai tent house fire prevention design fire alarm membrane
  • 相关文献

参考文献3

  • 1克劳斯-迈克尔,科赫.膜结构建筑[M].大连:大连理工大学出版社,2007.
  • 2沈友弟,曾杰,杨风雷,等.世博园区消防规划技术研究[R].上海:上海市消防局,2008.
  • 3李淑惠.浅谈索膜结构的消防问题[J].消防科学与技术,2003,22(1):35-36. 被引量:4

共引文献3

同被引文献31

引证文献4

二级引证文献11

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部