摘要 天津陈塘热电厂某300 MW机组原有二次风量测量装置因堵灰严重,无法满足测量控制要求,对该装置进行了换型改造,更换为FLII-16型自清灰风量测量装置,更换后解决了堵灰问题,实现了准确测量的目的,实现了送风和锅炉自动可靠投入的目的,极大减少了维护工作量。 The original secondary air flow measuring device of a 300MW unit of Tianjin Chentang Thermal Power Plant was unable to meet the measurement and control requirement because of serious ash clogging,and it had been replaced by FLII-16 type air flow measurement device with soot self-cleaning and anti-blockage function.Then accurate measurement of secondary air flow was realized,and draft air and boiler automation were well put into operation,and the maintenance became easy.
作者 孙海波 张琦
出处 《东北电力大学学报》 2009年第6期88-91,共4页 Journal of Northeast Electric Power University
关键词 二次风 FLII-16型风量测量装置 自清灰 防堵 secondary air FLII-16 type air flow measuring device soot self-cleaning anti-blockage
  • 相关文献

参考文献5

  • 1J. H. Kim and K Shakourzadeh. Analysis and Modeling of Solid Flow in a Closed Loop Circulating Fluidized Bed with Secondary Air Injection. Power Techcnology. 2000, 111 : 179 - 185.
  • 2M. M. Fleming, A. M. Long, H. H. J. Van. Increasing Bioler Efficiency through Balancing Secondary Air Flow to Burners. Proceedings of the American Power Conference. 1996, 58 (2) : 1496 - 1500.
  • 3D. R. Goettling and L. Goettsching. Improving Airflow Measurements by a new Inlet Nozzle Contour. Technical and symposium Papers Presented at the 2003 Winter Meeting of the ASHRAE. 2003, 109(1) : 462 -472.
  • 4边立秀 周俊霞.热工控制系统[M].北京:中国电力出版社,2001..
  • 5张秀彬.热工测量原理及其现代技术[M].上海:上海交大出版社,1993.