GDxVCC在原发性开角型青光眼早期诊断中的应用 被引量:1

The Application of GDxVCC in the Early Diagnosis of Primary Open Angle Glaucoma
下载PDF
导出
摘要 GDxVCC能够客观精确地测量视神经纤维层厚度,通过分析GDxVCC在原发性开角型青光眼(POAG)早期诊断中的特异性、敏感性,与视野的对应关系及重复性,来评价GDxVCC在POAG早期诊断的应用价值。在POAG的早期诊断中GDxVCC具有较高的特异性、敏感性,其中特异性、敏感性最高的指标是神经纤维指数,GDxVCC与视野的对应性关系不确切有待进一步研究,GDxVCC本身具有较好的重复性。 GDxVCC can accurately and objectively measure the thickness of retinal nerve fiber layer.The value of GDxVCC in early diagnosis of primary open angle glaucoma (POAG) can be estimated by analyzing the specificity and sensitivity,as well as the relationship and repeatability with visual field.GDxVCC has high specificity and sensitivity in the early diagnosis of POAG,of which,nerve fiber indicator is the best indicator,the relationship between GDxVCC and visual field is not exact,further researches are needed in the future,also,GDxVCC has high repeatability.
出处 《医学综述》 2010年第5期690-692,共3页 Medical Recapitulate
关键词 GDxVCC 原发性开角型青光眼 视神经纤维层厚度 视野 重复性 GDxVCC Primary open angle glaucoma Thickness of retinal nerve fiber layer Visual field Repeatability
  • 相关文献

参考文献6

二级参考文献63

  • 1袁援生,袁玲.视野检查的临床应用(二)[J].眼科研究,2006,24(4):337-339. 被引量:4
  • 2丁琦,杨蕾,严良,陆豪,张红英,熊毅.OCT检测原发性开角型青光眼神经纤维层厚度与视野光敏感度相关性分析[J].眼科新进展,2007,27(5):366-368. 被引量:7
  • 3Quigley HA, Dunkelberger BS, Green WR. Retinal ganglion cell atrophy correlated with automated perimetry in human eyes with glaucoma [ J ]. Am J Ophthalmol, 1989,107:453 - 464.
  • 4Quigley HA, Katz J, Derick RJ, et al. An evaluation of optic disc and nerve fiber layer examinations in monitoring progression of early glaucoma damage [ J ]. Ophthalmology, 1992,99 : 19 - 28.
  • 5Sanchez GC, Bowd C, Blumenthal EZ, et al. Using optical imaging summary data to detect glaucoma[J]. Ophthalmology,2001,108: 1812-1818.
  • 6Da Pozzo S, Iacono P, Marchesan R, et al. Scanning laser polarimetry with variable corneal compensation and detection of glaucomatous optic neuropathy [J]. Graefe' s Arch Clin Exp Ophthahnol, 2005, 243:774-779.
  • 7Reus N J, Lemij HG. Diagnostic accuracy of the GDxVCC for glaucoma [ J]. Ophthalmology ,2004,111 : 1860 - 1865.
  • 8Weinreb RN, Dreher AW, Coleman A, et al. Histopathologic validation of Fourier ellipsometry measurements of retinal nerve fiber layer thickness [ J ]. Arch Ophthalmol, 1990,108:557 - 560.
  • 9Morgan JE, Waldock A, Jeffery G, et al. Retinal nerve fiber layer polarimetry: histological and clinical comparison [ J ]. Br J Ophthalmol, 1998,82: 684 - 690.
  • 10袁援生,陈晓明.现代临床视野检测[M].北京:人民卫生出版社,2000:191.

共引文献10

同被引文献7

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部