摘要
在"神光Ⅱ"实验条件下,通过在半腔靶底部的漏口来测量内爆靶丸附近的M带X射线发射的角分布.介绍了试验中采用的诊断方法和试验方法,并给出了典型的实验结果.此外,利用视角因子程序,对该实验的X射线角分布进行了模拟.经过对比,发现实验结果与视角因子程序模拟结果相符,从半腔靶底部漏口出射的M带X射线不遵从cosθ分布.实验结果和模拟结果的比较有助于提高对黑腔物理图像的理解,并为内爆实验设计提供实验依据.
Measurement of radiation field near a implosion pellet M band X-ray is a import ant area in ICF research. On the SG Ⅱ laser facility, M band X-ray from Au pla sma was measured in half-hohlraum radiation from the end. The experimental set-up and typical result were given. And we’ve also used the view-factor program to simulate this experiment. The results indicate that angular distribution of M band X-ray from the end of half-hohlraum doesn’t assume linear relationship with the cosine of eradiating angle. The results are useful for the research of implosion experiment and target design.
出处
《物理学报》
SCIE
EI
CAS
CSCD
北大核心
2010年第3期1913-1916,共4页
Acta Physica Sinica
基金
中国工程物理研究院科学技术发展基金(批准号:2007B08002)
高温高密度等离子体物理国防科技重点实验室基金(批准号:9140C6801020801)资助的课题~~
关键词
间接驱动
X射线角分布
视角因子
indirect drive
X-ray angular distribution
view-factor