摘要
用了示波极谱滴定法测定硝酸盐样品中铷和铯的含量,回收率为9778%~1003%,相对标准偏差均值为021%。该法以示波极谱图形突变来确定滴定终点,终点直观,不受溶液颜色、沉淀的影响,具有准、快、简、省的特点。
Rubidium and Cesium in sample of nitrate were determined by oscillographic titration.The end point,being indicated by a sudden change of oscillogram,was not affected by the color of the solution and the precipitation.The recoveries ranged from 97 78% to 100 3% with a RSD of 0 21%.The proposed method proved accurate,precise and simple.
出处
《分析测试学报》
CAS
CSCD
1998年第5期84-86,共3页
Journal of Instrumental Analysis