摘要
本文叙述了采用高效液相色谱法,以甲醇作流动相测定烯效唑含量。该方法标准偏差为0.3807,变异系数0.51%,平均回收率100.14%,方法线性关系良好,相关系数为0.9999。
The quantitative analysis of uniconazole was undertaken by HPLC,using methanol as mobile phase, the results showed that the standard deviation, variation coefficient and average recovery were 0.3807,0.51% and 100.14% respectively. The method gave a good linear response ,correlation coefficient was 0.9999.
出处
《农药科学与管理》
CAS
1998年第1期7-7,10,共2页
Pesticide Science and Administration