分析了"1+4"热连轧机测厚系统的组成及其结构特点,介绍了"1+4"热连轧机测厚系统的工作原理,提出并分析了操作维护人员在实际工作中应注意的一些问题。
The constitution,structure and operation principle of IMS thickness measuring gauge for "1 +4"hot tandem mill were introduced and described.Some problems that should be paid attention during the operation were analyzed as well.