摘要 目的分离血小板验证Bayer ADVIA 2120全自动血细胞分析仪的血小板线性范围。方法按IS015189的EP6-A要求,从250份样本中分离血小板对血小板线性范围进行验证。结果任意混合多样本分离血小板取得高浓度血小板,Bayer ADVIA 2120检测血小板批内和天间不精密度为3.0%和3.6%,携带污染率为0.02%,血小板在21~4918×10^9/L范围内呈一项次线性关系。结论可不分血型混合血浆,通过分离、浓缩取得高浓度血小板;Bayer ADVIA 2120全自动血细胞分析仪检测血小板精密,线性良好,线性范围宽,携带污染率低,是一台检测血小板性能良好的全自动血细胞分析仪。 Objective To verify the linear range of the platelets at Bayer ADVIA 2120 analyzer. Methoils According to ISO15189 EP6-A, platelet separated from 250 samples to verify the linear range at Bayer ADVIA 2120 analyzer. Results High eoneentrations of platelet can obtained from mixing multi samples. Coefficient of Varianee of within-run and between-day was 3.0% and 3.6% ,earry-over was 0. 02% ,platelet range at 21- 4918 × 109/L Showed a linear relationship. Conclusion Regardless of blood type, high concentrations of platelet can obtained from mixing multi samples. Bayer ADVIA 2120 automated hematology analyzer has good feafures of precision, linearity, low carry-over,is a perfect performance analyzer.
出处 《中国临床实用医学》 2010年第3期68-70,共3页 China Clinical Practical Medicine
关键词 BAYER ADVIA 2120 全自动血细胞分析仪 线性范围验证 血小板分离 多样本 Bayer ADVIA 2120 Full-automatic blood cell' s analyzer The linear range Separation of platelets Multi-samples
  • 相关文献

参考文献5

  • 1International Council for Standardization in Hematology. Guidelines for the evaluation of blood cell analyzerincluding those used for the differential leucocyteand reticulocyte counting and cell marker application. Prepared by the ICSH expert panal on cytometry. Clin Lab Haemat, 1994,16 : 157-174.
  • 2Department of Health and Human Services. Centers for Medicare &Medicaid Services.
  • 3吴新忠,庞鑫,罗福东,陈富,熊小泉.Bayer ADVIA 2120全自动血细胞分析仪的性能评价[J].现代医学仪器与应用,2007,0(6):62-64. 被引量:5
  • 4NCCLS. EP6-A. Evaluation of the linearity of quantative analytical methods procedure: a statistical approach. Approved guideline, 2003 : 1-60.
  • 5杨冬燕,樊小蓉,潘冀雅,朱静,海鸥,黎美君,王娟娟,余梅贵.手工分离浓缩血小板的全过程质量控制[J].重庆医学,2007,36(21):2153-2154. 被引量:1

二级参考文献4

  • 1马曙轩,欧阳锡林,刘景汉.手工采集血小板的制备与临床应用[J].中国输血杂志,2004,17(5):372-374. 被引量:24
  • 2中华人民共和国国家质量监督检验检疫总局发布.中华人民共和国国家标准《全血及成分血质量要求》(GB18469-2001)[S].北京:2001:1
  • 3中华人民共和国国家质量监督检验检疫总局发布.中华人民共和国国家标准《献血者健康检查要求》(GB18467-2001)[S].北京:2001:1.
  • 4Scott Murphy. Platelet from pooled buffy coasts: an update[J].Transfusion, 2005,45 (4) : 642.