期刊文献+

使用Pentacam测量分析系统对近视眼眼前节测量 被引量:2

Measurement of ocular anterior segment in myopic patients with Pentacam Scheimpflug system
下载PDF
导出
摘要 目的应用Pentacam三维眼前节分析系统对不同屈光度近视眼眼前节各部位进行测量,为临床使用提供依据。方法564例(1128眼)按等效球镜分为A、B、C和D组(低度近视眼组、中度近视眼组、高度近视眼组和超高度近视眼组),分别测量眼前节各部位并对结果进行分析比较。结果角膜前表面屈光力分别为43.31±1.35、43.71±1.34、43.77±1.50、43.85±1.30,组间差异具有统计学意义,其余测量指标与屈光度变化无关。结论Pentacam测量可以全面、便捷、准确的分析眼前节,对于屈光手术具有较好的临床指导意义。 Objective To measure the ocular anterior segment in myopia patients with Pentacam Scheimpflug system in order to provide the clinical data of myopia. Methods Five hundred and sixty-four myopia patients (1 128 eyes) were divided into low myopia group (292 eyes), moderate myopia group (320 eyes), high myopia group (322 eyes), and super high myopia group (194 eyes)according to the mean spherical equivalent. The ocular anterior segments at different sites of myopia patients were measured with Pentacam Scheimpflug imaging system and comparatively analyzed. Results The anterior keratometry was 43.31±1.35, 43.85±1.30, 43.77±1.50, 43.85±1.30 (P0.05), respectively, in the 4 groups. The changes in myopic diopter were not associated with the other measured parameters (P0.05). Conclusion The ocular anterior segments in myopia patients can be comprehensively, rapidly, and accurately analyzed with Pentacam Scheimpflug system, which is of clinical significance in refractive surgery.
出处 《军医进修学院学报》 CAS 2010年第3期230-231,234,共3页 Academic Journal of Pla Postgraduate Medical School
基金 全国博士后科学基金面上项目(20090451511)
关键词 近视 眼前节 PENTACAM系统 Myopia Ocular Anterior Segment Pentacam System
  • 相关文献

参考文献8

  • 1Khu PM, Kashiwagi T. Quantitating nuclear opacification in color Scheimpflug photographs [ J ] . Invest Ophthalmol Vis Sci, 1993, 34 : 130-136.
  • 2Gardner BG, Taub MB. New diagnositic device in Eyecare [ J ] . RevOptom, 2004, 15 : 79-85.
  • 3O'Donnell C, Maldonado-Codina C. Agreement and repeatability of central thickness measurement in normal corneas using uhrasound pachymetry and the OCULUS Pentacam [ J ] . Cornea, 2005, 24 : 920-924.
  • 4Barkana Y, Gerber Y, Elbaz U, et al. Central corneal thickness measurement with the Pentacam Scheimpflug system, optical low-coherence reflectometry pachymeter, and ultrasound pachymetry [ J ]. J Cataract Refract Surg, 2005, 31 : 1729-1735.
  • 5Frano S, Almeida JB, Parafita M. Corneal thickness and elevation maps Computed from optical rotary scans [ J ] . J Refract Surg, 2004, 20 : $576-580.
  • 6何燕玲,元力,黎晓新,胡亦文.Pentacam三维眼前节分析诊断系统对近视眼眼前节的测量[J].眼科研究,2007,25(11):872-874. 被引量:31
  • 7Kent C. The anterior chamber from every angle [ J ] . Rev Ophthalmol, 2005, 12 : 33-38.
  • 8Haji SA, Ramonas K, Potapova N, et al.Intraoperative correction of induced astigmatism after spherical correction of hyperopia with conductive keratoplasty [ J ] . Eye Contact Lens, 2005, 31 : 76- 79.

二级参考文献10

  • 1徐亮,张莉,马英楠,王鑫,王赟,王云松,王爽.三维前房分析仪对40岁以上人群前房形态测量的初步研究[J].眼科,2005,14(2):85-87. 被引量:15
  • 2李惠玲,杨鹤超,于荣国,高莉,周学军.近视LASIK术前角膜后表面地形图的测量分析[J].眼外伤职业眼病杂志,2005,27(12):905-907. 被引量:4
  • 3何燕玲,黎晓新,鲍永珍,刘国栋,胡亦文.Pentacam系统与A超角膜测厚仪测量瞳孔中心角膜厚度的比较[J].中华眼科杂志,2006,42(11):985-988. 被引量:28
  • 4Buehl W, Stojanac D, Sacu S, et al. Comparison of three methods of measuring corneal thickness and anterior chamber depth [ J ]. Am J Ophthalmol,2006,141 : 7 - 12.
  • 5Kaluzny B, Koszewska-Kolodziejczak A. Changes of eye refraction, corneal power and lens power during growth in emmetropia, myopia and hyperopia [ J]. Klin Oczna,2005,107:464 - 467.
  • 6Greene PR. Optical constants and dimensions for the myopic, hyperopic and normal rhesus eye [ J ]. Exp Eye Res, 1990,51 (4) : 351 - 359.
  • 7Czepita D, Filipiak D. Corneal radius of curvature among people with myopia[J]. Klin Oczna,2003,105(3 -4) : 155 - 156.
  • 8Budak K, Khater TT, Friedman N J, et al. Evaluation of relationships among refractive and topographic parameters[ J]. J Cataract Refract Surg, 1999,25: 814 - 820.
  • 9Iskander NG, Penno EA, Peters NT, et al. Accuracy of Orbscan pachymetry measurements and DHG ultrasound pachymetry in primary laser in situ keratomileusis and LASIK enhancement procedures [ J ]. J Cataract Refract Surg,2001,27: 681 - 685.
  • 10高文婷,刘后仓,郭伟.近视眼角膜中央厚度与眼压和屈光度的关系[J].眼视光学杂志,2004,6(1):16-18. 被引量:8

共引文献30

同被引文献19

引证文献2

二级引证文献11

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部