摘要 为了降低厂用电率和提高系统自动化水平,潍坊发电有限公司08年分别对3、4号机凝结水泵进行了高压变频技术改造。本文介绍了在670MW机组凝结泵上应用高压变频技术的改造方案,分析了凝结泵高压变频技术改造后的良好节能效果。 The Condensate pump A of Weifang Power Plant CO..Ltd. No.3 and 4 unit were installed with high voltage frequency conversion in order to reduce station power, consumption rate and evaluate system automation level. This paper introduces the plan on the application of variable frequency drive technology in the condensate pump of the 670MW units, the notable energy-saving effect of variable frequency drive technology in the condensate pump is analyzed.
作者 葛峰
出处 《山东电力高等专科学校学报》 2010年第1期73-76,共4页 Journal of Shandong Electric Power College
关键词 变频 凝结水泵 一拖二 节能 HV frequency conversion condensate pump two pumps driven by shared one converter energy- savin
  • 相关文献

参考文献4

  • 1吴忠智.变频器应用手册[M].北京:机械工业出版社,2004.
  • 2韩安荣.通用变频器及其应用[M].北京:机械工业出版社,2004.
  • 3高压变频器调速系统HARSVERT-A系列技术手册[R].北京利德华福电气技术有限公司BLHB01-004.1.
  • 4华电潍坊电厂高压变频器BLH-CM系列强制式密闭冷却装置使用说明书[R].北京利德华福电气技术有限公司.2008.