摘要 冠状动脉粥样硬化性心脏病是许多国家首要的死亡原因,正电子发射断层扫描可以清晰地显示心肌灌注,室壁运动和心肌活性,成为诊断冠状动脉粥样硬化性心脏病的重要手段。而正电子发射断层扫描和多层螺旋X线断层扫描仪的融合,把钙化积分和无创性的X线断层扫描仪血管造影加入心肌灌注显像和代谢显像,为冠状动脉粥样硬化性心脏病的诊断提供形态和功能方面的信息。 Coronary heart disease is a leading cause of death in many countries. Positron emission tomography is an imaging technique that can capture cardiac perfusion, wall motion, and myocardial viability. Positron emission tomography plays an important role in the diagnosis of coronary heart disease. The combination of multislice computed tomography coronary angiography and myocardial perfusion imaging provides both anatomical and functional information of coronary heart disease.
作者 杨杨 褚俊
出处 《心血管病学进展》 CAS 2010年第2期241-244,共4页 Advances in Cardiovascular Diseases
基金 安徽省卫生厅科研课题经费资助09A091
关键词 X线断层扫描/正电子发射断层摄影术 心肌灌注显像 冠状动脉粥样硬化性心脏病 PET/CT myocardial perfusion imaging coronary heart disease
  • 相关文献

参考文献32

  • 1Jadvar H,Parker JT. A Clinical PET and PET/C [ M ]. London:Springer Publising, 2005.69-84.
  • 2Frederic H, Fahey DSC. Position emission tomography instrumentation [ J ]. Radiol Clin North Am,2001,39:919-929.
  • 3Berman DS,Hayea SW,Shaw LJ,et al. Recent advances in myocardial perfusion imaging [ J ]. Curr Prob Card,2001,26:62-70.
  • 4Bergmann SR. Cardiac positron emission tomography [ J ]. Sem Nucl Med, 1998, 28(4) :320-340.
  • 5DiFilippo FP, Brunken RC, Neumann DR, et al. Intitial clinical experience with Rb-82 cardic PET imaging on a PET/CT system [ J ]. J Nucl Med, 2004,45 : 117.
  • 6DiCarli MF, Dorbala S, Mishra R, et al. Clincal myocardial perfusion PET/CT imaging with rubidlum-.82 : initial experience in 94 patients [ J ]. J Nucl Med, 2004,45:117.
  • 7Wassenaar RW, Wells RG, DeKemp R, et al. Clinical evaluation of CT versus Ge-68 attenuation correction in cardic PET imaging [ J ]. J Nucl Med, 2004,45: 118.
  • 8Wu TH,Huang YH,Lee JJ,et al. Radiation exposure during transmission measurements:comparison between CT and germanium based techniques with a current PET scanner[ J]. Eur J Nucl Med Mol Imaging,2004,31:3843.
  • 9Deloar HM ,Fujiwara T,Shidahara M ,et al. Estimation of absorbed dose for 18F- fluorodeoxy 2D glucose using whole body positron emission tomography and magnetic resonance imaging [ J ]. Clin Focus,2005,20 ( 1 ) : 51-53.
  • 10Go RT, Marwick TH, MacIntyre W J, et al. A prospective comparison of rubidium-82 PET and thallium-201 SPECT myocardial perfusion imaging utilizing a single dipyridamole stress in the diagnosis of coronary artery disease [ see comments] [J]. J Nucl Med,1990,31:1899-1905.

同被引文献4

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部