摘要 目的比较5种手持根管器械的成形能力。方法用光学显微镜观察5种手持根管器械常规法预备弯曲人工根管后的根管形态变化。结果所有标本未发现根尖拉开、肘部形成和穿孔。K-Flex组有75%的标本出现台阶,台阶的出现与根尖部树脂屑栓的形成有很密切的关系。K-Flex组和H挫组的根尖偏移较大,与K针组比较,有显著性差异(PMO.05),其余各组之;b]无显著性差异(P>0.05)。结论通过综合评价5种手持根管器械预备弯曲人工根管的切削能力和成形能力,作者认为Unifile和K型挫是首选的器械。 Objective To compared the shaping ability of five handle endodonticintruments. Methods The canal shape of prepared artificial root canals with five handleendodontic instruments were observed by light-microscope. Results Apical zips, elbows andperforations were not found. Ledges occurred in specimens of K-Flex group and they wererelating to resinous plugs. The apical transportations were relating to resinous plugs. Theapical transportations of K--Flex group and H file group are much greater than other groups.Conclusion Unifile or K file is first choice to prepare curved artificial root canals with routinepreparation technique by comprehensive evalution of the cutting ability and shaping ability offive handle endodontic instruments.[
出处 《上海口腔医学》 CAS CSCD 1998年第4期221-223,共3页 Shanghai Journal of Stomatology
关键词 手持根管器械 成形能力 人工根管 handle endodontic instrument shaping ability artificial root canalroutine preparation technique
  • 相关文献

参考文献1

共引文献8

同被引文献24

  • 1范兵.扩大弯曲根管的平衡力法及其研究进展[J].国外医学(口腔医学分册),1994,21(3):149-153. 被引量:3
  • 2凌均 高燕.牙髓治疗临床新进展[A]..见:华南国际口腔医疗技术研讨会论文集[C].广州,2003.215-223.
  • 3王晓仪 王哲明 韦曦 等.现代根管治疗学[M].北京:人民卫生出版社,2002.42.
  • 4Gary chueng.镍钛机用根管器械的临床应用和注意事项[J].牙体牙髓牙周病学杂志,1999,9:7-7.
  • 5Sehirrmeister JF, Strohl C, Altenburger M J, et al. Shaping ability and safety of five different rotary nickel-titanium instruments compared with stainless steel hand instrumentation in simulated carved root canals [J]. Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 2006, 101(6):807-813.
  • 6Schafer E, Vlassis M. Comparative investigation of two rotary nickel -titanium instruments: ProTaper versus RaCe. Part 1. Shaping ability in simulated curved canals[J]. Int Endod J, 2004,37(4):229- 238.
  • 7Guelzow A, Stamn O, Martus P, et al. Comparative study of six rotary nickel-titanium systems and hand instrumentation for root canal preparation [J]. Int Endod J,2005,38(10):743-752.
  • 8Calberson FL, Deroose CA, Hommez GM, et al. Shaping ability of ProTaper Nickel-Titanium files in simulated resin root canals [J]. Int Endod J,2004,37(9) :613-623.
  • 9Alapati SB, Brantley WA, Svec TA, et al. Proposed role of embedded dentine chips for the clinical failure of nickel-titanium rotary instruments [J]. J Ended, 2004, 30(5):339-341.
  • 10Tompson SA, Dummer PMH. Shaping ability of Mity Roto 360° and Naviflex rotary nickel-titanium instruments in simulated root canals. Part 2 [J]. J Endod 1998,24(2) :135-142.

引证文献4

二级引证文献27

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部