摘要
本文对拟诊或可疑冠心病(CAD)者和正常人40例全部进行多巴酚丁胺彩色动力技术(CK)超声心动图负荷试验(D—CK)和多巴酚丁胺心电图负荷试验(D—ECG),然后再与冠脉造影结果进行对照.结果表明:D—CK和D—ECC诊断CAD的敏感性、特异性、准确性分别为100%和80.95%、83.33%和75%、93.94%和78.79%.应用D—CK能够提高对室壁缺血部位的检测,优于D—ECG.D—CK为CAD诊断提供了一种安全、可靠的方法.
In this studies, 40 subjects with and without CAD suspected underwent the dobutamine stress color kinetic e-chocardiography(D - CK) and dobutamine stress electrocardiogram test (D - ECG) .The results showed: Compared with coronary arteriography, the diagnostic sensitivity, specificity and accuracy were 100% & 80.95% , 83. 33% & 75%and 93.94% & 78.79% respectively for detecting CAD by D - CK and D - ECG. Detection for ischmia area of ventricular wall by D - CK was better than D - ECG.In the conclusion, D - CK is the safe.accurate and reliable method for diagnosing coronary artery disease and detecting myocardial ischemia.
出处
《中国心血管杂志》
1998年第6期436-439,共4页
Chinese Journal of Cardiovascular Medicine
关键词
彩色动力技术
多巴酚丁胺
负荷试验
冠心病
Color kinesis Dubutamine stress test Electrocardiogram Coronary artery disease