期刊文献+

燃料电池的微尺度测试技术 被引量:1

Micro-scale measuring and testing techniques for fuel cells
下载PDF
导出
摘要 随着燃料电池体积的微小化,传统的测试技术已经不再适合微型燃料电池某些参数的测试。在这种情况下,基于微机电系统的微尺度测试技术被逐步引入燃料电池的测试中。本文对燃料电池的温度、湿度及燃料浓度等参数的微小型测试技术进行了回顾,同时也对引入显微镜等设备的微型燃料电池可视化系统进行了讨论。最后对燃料电池的微尺度测试技术发展前景进行了分析。 With the microminiaturization of fuel cells, the traditional testing techniques is no longer suitable to some parameters test for micro fuel cells. Therefore, micro-scale measuring and testing techniques based on micro-electromechanical systems (MEMS) is introduced into fuel cells measurement. In this paper the measurement methods for temperature, humidity and concentration testing in fuel cells are reviewed. Visualization system of two-phase flow based on microscopy for micro fuel cells is discussed. And the long-term potential of micro scale measuring and technologies for fuel cells are also analyzed.
出处 《现代化工》 CAS CSCD 北大核心 2010年第3期87-92,共6页 Modern Chemical Industry
基金 国家自然科学基金项目(50976006) 北京市优秀人才培养项目(20081D0501500167)
关键词 燃料电池 微型机电系统 测试 电化学 fuel cells micro electro mechanical systems testing electrochemistry
  • 相关文献

参考文献44

  • 1Jiang Y Q, Wang X H, Zhong L Y, et al. Design, fabrication and testing of a silicon-based air-breathing micro direct methanol fuel cell [ J]. Journal of Micromechanics and Microengineering,2006,16 (9) :S233 - S239.
  • 2Zhao T S, Wong C W, Ye Q, et al. Experimental investigations of the anode flow field of a micro direct methanol fuel cell[J]. Journal of Power Sources ,2006,155 ( 2 ) :291 - 296.
  • 3Kenis P J A, Yeom J, Jayashree R S, et al. Passive direct formic acid microfabricated fuel cells[J]. Journal of Power Sources,2006, 160(2) :1058 - 1064.
  • 4Baqlio V, Stassi A, Marera F V, et al. Optimization of properties and operating parameters of a passive DMFC mini-stack at ambient tem-perature [ J ]. Journal of Power Sources, 2008,180 ( 2 ) : 797 - 802.
  • 5Lee C Y,Wu G W,et al. In situ diagnosis of micro metallic proton exchange membrane fuel cells using micro sensors [ J ]. Journal of Power Sources,2007,172 ( 1 ) : 363 - 367.
  • 6Zhang Y, Lu J, Zhou S H, et al. Application of nanoimprint technology in MEMS-based micro direct-methanol fuel cell (μ-DMFC) [J]. Journal of Micro Electromechanical Systems, 2008,17 (4) : 1020 - 1028.
  • 7Yang W M,Chou S K,Shu C. Effect of current-collector structure on performance of passive micro direct methanol fuel cell[ J]. Journal of Power Sources,2007,164 (2) :549 - 554.
  • 8Zhu Y L, Liang J S, Liu C, et al. Development of a passive direct methanol fuel cell ( DMFC ) twin-stack for long-term operation [J]. Journal of Power Sources ,2009,193 (2) :649 - 655.
  • 9Lim S W, Kim S W, Kim H J, et al. Effect of operation parameters on performance of micro direct methanol fuel cell fabricated on printed circuit board[ J]. Journal of Power Sources,2006,161 ( 1 ) : 27 - 33.
  • 10Shou S H, Kuan M C. Channel and rib geometric scale effects of flow field plates on the performance and transient thermal behavior of a micro-PEM fuel cell[J]. Journal of Power Sources, 2007,173 ( 1 ) :222 - 232.

同被引文献35

  • 1肖劲松,李超,郭航,马重芳.微型薄膜瞬态热流计的研究与开发[J].北京工业大学学报,2006,32(12):1116-1120. 被引量:4
  • 2Pattekar A V, Kothare M V. A Microreactor for Hydrogen Production in Micro Fuel Cell Applications [ J ]. Journal of Micro Electromechanical Systems ,2004,13 ( 1 ) :7 - 18.
  • 3He S, Mench M M, Tadigadapa S. Thin film temperature sensor for real-time measurement of electrolyte temperature in a polymer electrolyte fuel cell [ J ]. Sensors and Actuators A ,2006,125 (2) :170 - 177.
  • 4Lee C Y, Huang R D, Chuang C W. Novel Integration Approach for In situ Monitoring of Temperature in Micro-direct Methanol Fuel Cell. Japanese Journal of Applied Physics [ J ]. 2007,46 (10A) : 6911 - 6914.
  • 5Lee C Y, Lee S J, Hsieh C L. Application of Micro Sensors on Diagnosis of Micro Fuel Cells [ C ]//Bangkok, Thailand. Proceedings of the 2nd IEEE International Conference on Nano/Micro Engineered and Molecular Systems ,2007:434 - 437.
  • 6Lee C Y, Wu G W, Hsieh C L. In situ diagnosis of micrometallic proton exchange membrane fuel cells using microsensors [ J ]. Journal of Power Sources,2007,172( 1 ) :363 -367.
  • 7Lee C Y, Hsieh W J, Wu G W. Embedded flexible micro-sensors in MEA for measuring temperature and humidity in a micro-fuel cell [ J]. Journal of Power Sources,2008,181 (2) :237 - 243.
  • 8Zhang Q, Wang X H, Zhu Y M,et al. Optimized temperature control system integrated into a micro direct methanol fuel cell for extreme environments [ J ]. Journal of Power Sources, 2009,192 ( 2 ) : 494 - 501.
  • 9Zhang G H, Guo L J, Ma L Z, et al. Simultaneous measurement of current and temperature distributions in a proton exchange membrane fuel cell [ J]. Journal of Power Sources, 2010, 195 ( 11 ) : 3597 - 3604.
  • 10Adzic M, Heitor M V, Santos D, et al. Design of dedicated instrumentation for temperature distribution measurements in solid oxide fuel cells[ J]. Journal of Applied Electrochemistry, 1997,27 (12) : 1355 - 1361.

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部