目的建立火焰原子吸收法测定双份饭中铁、锌、钙的方法。方法样品经馄合酸(硝酸+高氯酸=4+1)消解后,钙用20g/L的氧化镧溶液定容,铁、锌用纯水定容后直接测定。结果铁浓度在0.20~2.00μg/ml范围时,相关系数为0.9996,加标回收率为96.5%~102.7%,检出限(3σ)0.006μg/ml;锌浓度在0.10~1.50μg/ml范围时,相关系数为0.9997,加标同收率为95.0%~101.5%,检出限(3σ)0.004μg/ml;钙浓度在1.00~10.00μg/ml范同时,相关系数为0.9994,加标回收率为96.8%~103.6%,检出限(3σ)0.008μg/ml。结论该方法简便快捷,测定结果准确可靠,适合于双份饭分析。
[Objective]To establish the method of determining Fe,Zn and Ca in duplicate food portions by flame atomic absorption spectrometry.[Methods]The samples were digested with the mixed acid of V(HNO3)+V(HClO4)=4+I,then Ca was diluted with lanthanum oxide of 20 g/L.Fe and Zn were diluted with pure water before determination.[Results]The concentration of Fe ranged from 0.20~2.00 μg/ml,the correlation coefficient was 0.9996,the recovery of standard addition was 96.5%~102.7% and the detection limit(3 σ) was 0.006 μg/ml.When the concentration of Zn ranged from 0.10~1.50μg/ml,the correlation coefficient was 0.9997,the recovery of standard addition was 95.0%~101.5% and the detection limit(3 σ) was 0.004 μg/mL.At the concentration range of 1.00~10.00 μg/ml,the correlation coefficient was 0.9994,the recovery of standard addition was 96.8%~103.6% and the detection limit(3 σ) was 0.008 μg/mL for Ca.[Conclusion]The method is simple,rapid,reliable and suitable for determination of duplicate food portions.
出处
《职业与健康》
CAS
2010年第6期629-630,共2页
Occupation and Health
关键词
火焰原子吸收法
双份饭
铁、锌、钙
Flame atomic absorption spectrometry
Duplicate portion
Fe
Zn and Ca