核磁共振兼容手术机器人的驱动方式分析 被引量:6

Drive method analysis of magnetic resonance imaging compatible surgical robots
下载PDF
导出
摘要 核磁共振兼容手术机器人的驱动问题是研究图像导航手术机器人的一个重要内容。首先分析了核磁共振兼容手术机器人存在的问题,介绍了国内外研究者关于核磁共振兼容手术机器人驱动方式的使用情况,探讨了各种驱动方式的特点,得出了各项驱动方式在核磁共振环境下的使用性能,并对其发展方向作出了展望。 The research on the drive methods of Magnetic Resonance Imaging compatible surgical rohots is an important content in the field of the image-guided surgical robot. Firstly, the existing problems on the MRI-compatible robots were studied. Secondly, status of research abroad and home on the application of actuators in the MRI-eompatible equipments was introduced. Then the charac- teristics of various actuators were discussed and analyzed. Finally, the future development trends were forecasted based on the previous analysis.
出处 《机械设计》 CSCD 北大核心 2010年第3期44-49,共6页 Journal of Machine Design
基金 哈尔滨市科技创新人才专项基金资助项目(RC2006LX006004)
关键词 核磁共振 手术机器人 驱动方式 MRI surgical robot drive method
  • 相关文献

参考文献42

  • 1朴明波,付宜利,王树国.外科辅助手术机器人的发展及关键技术分析[J].机械设计与制造,2008(7):174-176. 被引量:11
  • 2洪在地,贠超,赵磊,王洋.核磁共振兼容手术机器人研究[J].中国生物医学工程学报,2008,27(4):621-629. 被引量:8
  • 3Chinzei K, Kikinis R, Jolesz F A. MR compatibility of mechatronic devices: design criteria [ C ]//1999 Medical Image Computing and Computer-Assisted Intervention, Cambridge, UK, 1999: 1020 - 1030.
  • 4Christoforou E G, Tsekos N V, ozcan A. Design and testing of a robotic system for MR image-guided interventions [ J]. J Intell Robot Syst, 2006, 47(2) : 175-196.
  • 5Tajima F, Kishi K, Nishizawa K, et al. A prototype master-slave system consisting of two MR-compatible manipulators with interchangeable surgical tools : part of a unified support system for diagnosis and treatment [ C]//2004 IEEE International Conference on Robotics and Automation, New Orleans, USA, 2004:2505 - 2510.
  • 6Koseki Y, Washio T, Chinzei K, et al. Endoscope manipulator for trans-nasal neurosurgery, optimized for and compatible to vertical field open MRI [ C ]//2002 Medical Image Computing and Computer-Assisted Intervention, Tokyo, Japan, 2002 : 114 - 121.
  • 7Krieger A, Susil R C, Menard C, et al.. Design of a novel MRI compatible manipulator for image guided prostate interventions [J]. IEEE Transactions on Biomedical Engineering, 2005, 52(2): 306-313.
  • 8Fichtinger G, Krieger A, Susil R C, et al. Transrectal prostate biopsy inside closed MRI scanner with remote actuation under real-time image guidance[ C ]//2002 Medical Image Computing and Computer- Assisted Intervention, Tokyo, Japan, 2002 : 91 - 98.
  • 9Fischer G S, Iordachita I, Csoma C, et al. MRI-compatible pneumatic robot for transperineal prostate needle placement [ J ]. IEEE/ ASME Transactions on Mechatronics, 2008, 13 ( 3 ) : 295 - 305.
  • 10Fischer G S, DiMaio S P, Iordachita, et al. Robotic assistant for transperineal prostate interventions in 3T closed MRI [ C ]//2007 Medical Image Computing and Computer-Assisted Intervention, Brisbane, Australia, 2007 : 425 - 433.

二级参考文献44

  • 1薛晓虎.液压系统缝隙内流体泄漏特性的分析[J].机械工程学报,2004,40(6):75-80. 被引量:37
  • 2邵兵 SunLining DuZhijiang FuLixin.The design of the robot assisted magnetic resonance imaging guidance for minimally invasive surgery system[J].High Technology Letters,2005,11(2):167-170. 被引量:1
  • 3唐粲,超贠,栾胜.一种新型医疗机器人运动学及灵活性分析[J].北京航空航天大学学报,2005,31(7):748-752. 被引量:16
  • 4Han Koo Lee, Gi Sang Choi. Gi Heung Choi. A study on tracking position control of pneumatic actuators [ J ]. Mechatronics,2002(12) :813-831.
  • 5Jihong Wang, Junsheng Pu, Philip Moore. A practical control strategy for servo-pneumatic actuator systems[ J ]. Control Engineering Practice, 1999(7) : 1483-1488.
  • 6Massimo Sorli, Giorgio Figliolini, Stefano Pastorelli. Dynamic model of a pneumatic proportional pressure valve[J]. ASME International Conference on Advanced Intelligent Mechatronics Proceedings, 2001(7) :630-635.
  • 7Edmond Richer, Yildirim Hurmuzlu. A high performance pneumatic force actuator system: part I-nonlinear mathematical model[J], Transaction of the ASME,2000,122(9) :416-425.
  • 8James E. Bobrow, Brian W. McDonell, Modeling identification,and control of a pneumatically actuated, force controllable robot[J]. IEEE Transactions on Robotics and Automation. 1998, 14(5) : 732-742.
  • 9D B Ender. Implementation of Deadband Reset Scheduling for the Elimination of Stick-slip Cycling in Control Valves [J]. Journal A, 1997,38(1):11-15.
  • 10M A A Shoukat Choudhury, N F Thornhill, S L Shah. Modeling valve stiction [J]. Control Engineering Practice, 2005,13(1):641-658.

共引文献36

同被引文献46

  • 1郑树森.微创技术在普通外科中的应用现状和展望[J].中华外科杂志,2006,44(1):3-6. 被引量:6
  • 2孟志娟,彭光正.模糊PID控制在气动机械手中的应用[J].机床与液压,2006,34(7):194-195. 被引量:7
  • 3张志宇,吴博达,刘建芳.电流变技术的发展与应用[J].机床与液压,2007,35(6):203-207. 被引量:10
  • 4Dai J S. Surgical robotics and its development and progress[J]. Robotica, 2010, 28(2): 161.
  • 5Aigner F, Pallwein L, Pelzer A, et al. Value of magnetic reso- nance imaging in prostate cancer diagnosis[J]. World Journal of Urology, 2007, 25(4): 351-359.
  • 6Krieger A, Susil R C, Menard C, et al. Design of a novel MRI compatible manipulator for image guided prostate interventions [J]. IEEE Transactions on Biomedical Engineering, 2005, 52(2): 306-313.
  • 7Patriciu A, Petrisor D, Muntener M, et al. Automatic brachytherapy seed placement under MRI guidance[J]. IEEE Transactions on Biomedical Engineering, 2007, 54(8): 1499- 1506.
  • 8Muntener M, Patriciu A, Petrisor D, et al. Magnetic reso- nance imaging compatible robotic system for fully automated brachytherapy seed placement[J]. Urology, 2006, 68(6): 1313- 1317.
  • 9Fischer G S, Iordachita I, Csoma C, et al. MRI-comPatible pneumatic robot for transperineal prostate needle placement[J]. IEEE/ASME Transactions on Mechatronics, 2008, 13(3): 295- 305.
  • 10Tokuda J, Fischer G S, Dimaio S P, et al. Integrated navigation and control software system for MRI-guided robotic prostate interventions[J]. Computerized Medical Imaging and Graphics, 2010, 34(1): 3-8.

引证文献6

二级引证文献35

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部