由于变频器价格昂贵,制约了其在煤矿排水系统中的广泛应用。由于变频调速转速下降过度会导致水泵扬程不够,限制了其变频调速范围,以至系统效率下降。通过利用离心泵优化组合的方法,可提高排水系统的控制精度与效率,降低了变频器容量及造价,值得推广。
QIAN Hongqi ZHOU Jie School of Mechanical Engineering, Guizhou University, Guiyang 550003, Guizhou, China Abstract: The high price of the frequency converter hampers the widespread use in the coalmine drainage system. And the excessively drop-off speed makes the insufficient pumping head and limits the frequeney conversion and speed regulation range so as to decrease the systematic efficiency. However, the optimal combination of the centrifugal pump could improve the control accuracy and efficiency of the drainage system and decrease volume and cost of the converter, which is worth promotion.
出处
《矿山机械》
北大核心
2010年第6期46-49,共4页
Mining & Processing Equipment
基金
贵州省科技厅工业攻关项目(2009-3041)
关键词
离心泵
优化组合
运行效率
centrifugal pumps
optimal combination
operational efficiency