期刊文献+

Polydimethylsiloxane Microchip Capillary Electrophoresis for Determination of Cholesterol

Polydimethylsiloxane Microchip Capillary Electrophoresis for Determination of Cholesterol
下载PDF
导出
摘要 Microchip capillary electrophoresis (MCE) has significant impact on diagnostic testing. One of the most importance in clinical analysis test is the determination of cholesterol level in blood, because its increase is associated with coronary heart disease which is a major cause of death world over. Polydimethylsiloxane (PDMS) was material used to make a MCE for determination of cholesterol. Hydrogen peroxide was generated from the oxidation of cholesterol with cholesterol oxidase (ChOx) and was detected electrochemically at a downstream gold (Au) wire electrode by amperometry. Various parameters, such as the detection potential, concentration of running buffer, pH of running buffer, separation voltage, injection time, and concentration of ChOx, were studied. The migration time of cholesterol is less than 100s and the calibration curve is linear from 50 mg.dL-1 to 250 mg-dL-1 with the coefficient of determination (R2) of 0.9955. Therefore, this proposed assay is very rapid and sensitive for the detection of cholesterol. Microchip capillary electrophoresis (MCE) has significant impact on diagnostic testing. One of the most importance in clinical analysis test is the determination of cholesterol level in blood, because its increase is associated with coronary heart disease which is a major cause of death world over. Polydimethylsiloxane (PDMS) was material used to make a MCE for determination of cholesterol. Hydrogen peroxide was generated from the oxidation of cholesterol with cholesterol oxidase (ChOx) and was detected electrochemically at a downstream gold (Au) wire electrode by amperometry. Various parameters, such as the detection potential, concentration of running buffer, pH of running buffer, separation voltage, injection time, and concentration of ChOx, were studied. The migration time of cholesterol is less than 100s and the calibration curve is linear from 50 mg.dL-1 to 250 mg-dL-1 with the coefficient of determination (R2) of 0.9955. Therefore, this proposed assay is very rapid and sensitive for the detection of cholesterol.
出处 《Journal of Electronic Science and Technology of China》 2010年第1期82-86,共5页 中国电子科技(英文版)
基金 supported by National Center of Excellence for Petroleum,Petrochemicals,and Advanced Materials,and the CU Graduate School Thesis Grant
关键词 CHOLESTEROL cholesterol oxidase microchip capillary electrophoresis polydimethylsiloxane. Cholesterol, cholesterol oxidase,microchip capillary electrophoresis, polydimethylsiloxane.
  • 相关文献

参考文献14

  • 1H.-L.Lee and S.-C.Chen,"Microchip capillary electrophoresis with electrochemical detector for precolumn enzymatic analysis of glucose,creatinine,uric acid and ascorbic acid in urine and serum," Talanta,vol.64,no.3,pp.750-757,Oct.2004.
  • 2C.D.Garcia and C.S.Henry,"Enhanced determination of glucose by microchip electrophoresis with pulsed amperometric detection," Analytica Chimica Acta,vol.508.no.1,pp.1-9,Apr.2004.
  • 3J.Wang,M.P.Chatrathi,C.Tian,and R.Polsky,"Microfabricated electrophoresis chips for simultaneous bioassays of glucose,uric acid,ascorbic acid,and acetaminophen," Analytical Chemistry,vol.72,no.11,pp.2514-2518,Jun.2000.
  • 4J.Wang and M.P.Chatrathi."Microfabricated electrophoresis chip for bioassay of renal markers," Analytical Chemistry,vol.75,no.3,pp.525-529,Feb.2003.
  • 5C.D.Garcia and C.S.Henry,"Direct determination of carbohydrates,amino acids,and antibiotics by microchip electrophoresis with pulsed amperometric detection," Analytical Chemistry,vol.75,no.18,pp.4778-4783,Sep.2003.
  • 6G.Ping,B.Zhu,M.Jabasini,F.Xu,H.Oka,H.Sugihara,and Y.Baba,"Analysis of lipoproteins by microchip electrophoresis with high speed and high reproducibility," Analytical Chemistry,vol.77,no.22,pp.7282-7287,Nov.2005.
  • 7A.-J.Wang,J.-J.Xu,and H.-Y.Chen,"Proteins modification of poly(dimethylsiloxane) microfluidic channels for the enhanced microchip electrophoresis," Journal of Chromatography A,vol.1107,no.1-2,pp.257-264,Feb.2006.
  • 8K.Miyaki,H-L.Zeng,T.Nakagama,and K.Uchiyama,"Steady surface modification of polydimethylsiloxane microchannel and its application in simultaneous analysis of homocysteine and glutathione in human serum," Journal of Chromatography A,vol.1166,no.1-2,pp.201-206,Sep.2007.
  • 9K.Uchiyama,H.Nakajima,and T.Hobo,"Detection methods for microchip separations," Analytical and Bioanalytical Chemistry,vol.379,no.3,pp.375-382,Jun.2004.
  • 10S.K.Arya,A.K.Prusty,S.P.Singh,P.R.Solanki,M.K.Pandey,Datta M.,and B.D.Malhotra,"Cholesterol biosensor based on N-(2-aminoethyl)-3-aminopropyl trimethoxysilane self-assembled monolayer," Analytical Biochemistry,vol.363,no.2,pp.210-218,Apr.2007.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部