摘要 介绍了用于分析直流下局部放电序列信号的时间等待恢复模型及其假设,总结了基于基本参数放电幅值q和放电时间点t用于分析直流局部放电序列信号的多种放电谱图。利用自行研制的直流局部放电宽带检测系统获取了缺陷模型(空气中电晕、油纸绝缘的尖板、内部缺陷和沿面放电)在直流电压下的大量局部放电脉冲波形-时间序列。并对获取的脉冲波形-时间序列,使用脉冲群快速分类技术进行随机干扰脉冲剔除。在上述工作基础之上,进行了直流局部放电幅值-时间序列信号的相关性统计分析,给出了各缺陷模型对应的典型q-t、n-q、n-Δt和qsuc-q等多种直流局放谱图。试验结果分析表明,四种典型缺陷具有各自的放电特性,直流下局部放电发展过程符合时间等待恢复模型及其假设。这为基于幅值-时间序列的直流局放检测、识别提供了理论和试验依据。 A time recovery and lag model with its hypothesis to analysis partial discharge (PD) pulse sequence signals under DC voltage is introduced in this paper. A group of histograms to analysis DC PD are deduced from the two basic parameters, the discharge magnitude and arrive time which can be recorded by the PD measurement system. Three basic defect models of oil-paper insulation including corona, bounded cavity and surface discharge, and a typical discharge model of corona in air are described after the DC PD test and measurement system are shown. The PD measurement system has a special anti-noise technique which resorts to the characteristic of pulse waveshape signals in time and frequency domain to achieve fast separation of random pulsed noise signals. Test results of those defect models are analyzed and discussed respectively, which show that PD pulse sequence under DC voltage has its own characteristic with different defect models. Some of analyze results can be explained well with the time recovery and lag model with its hypothesis. This provides a test and theoretical evidence for study of detection and identification of PD pulse sequence under DC voltage.
出处 《电工技术学报》 EI CSCD 北大核心 2010年第3期164-171,共8页 Transactions of China Electrotechnical Society
基金 国家自然科学基金资助项目(50977075 50377034)
关键词 直流 局部放电 宽带测量 抗干扰 序列分析 Direct current partial discharge wide-band detection anti-interference sequence analysis
  • 相关文献

参考文献12

二级参考文献46

  • 1白建社,盛戈皞,江秀臣,曾奕.基于移动时间窗的直流局部放电特征提取方法[J].电力系统自动化,2005,29(14):55-59. 被引量:13
  • 2冉汉政,吴广宁,舒雯,张血琴,于成龙,刘华昌.膜纸复合储能电容器的直流局部放电信号分析方法[J].电工技术学报,2006,21(4):46-49. 被引量:16
  • 3Hoogenraad G,Beyer J.Digital HVDC partial discharge testing.Conference Record of the 2000 IEEE International Symposium on Electrical Insulation,2000:448~451.
  • 4Fromm U.Interpretation of partial discharges at DC voltages.IEEE Transaction on Dielectrics and Electrical Insulation,1995,2:761~770.
  • 5Fromm U,Morshuis P H F.Partial discharge classifycation at DC voltages.1995 IEEE International Conference on Conduction and Breakdown of Solid Dielectrics,1995,403~407.
  • 6Peter Morshuis.Unraveling the physics behind partial discharge PD data.Conference Record of the IEEE International Symposium on Electrical Insulation,1996.
  • 7舒雯,张血琴,吴广宁等.高压储能电容器缺陷识别的研究.第10届全国工程电介质学术会议论文集,2005,10:294~297.
  • 8MANSOR M, GHANI A B A, GHOSH P S. Partial Discharge Pattern Analysis Using Statistical Technique in XLPE Cable Under Various Soil Conditions. In: Proceedings of 2002 Annual Report Conference on Electrical Insulation and Dielectric Phenomena. Cancun(Mexico), 2002. Piscataway(NJ, USA) :IEEE, 2002. 707-711.
  • 9MORSHUIS P, HOOGENRAAD G. Partial Discharge Diagnostics for DC Equipment. In: Conference Record of the1996 IEEE International Symposium on Electrical Insulation,Vol 1. Montreal (Canada), 1996. New York(NY, USA):IEEE, 1996. 407-410.
  • 10丘昌容,王乃庆.电工设备局部放电及其测试技术[M].北京:机械工业出版社,1994.

共引文献113

同被引文献348

引证文献33

二级引证文献324

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部