摘要 目的评价Starclose血管缝合器在老年冠状动脉介入诊疗术中使用的安全性和疗效。方法204例老年冠脉介入诊疗术后患者,110例应用Starclose缝合器止血(缝合组),94例应用手工压迫止血方法止血(对照组),分别记录止血时间、下肢制动时间和手术相关并发症。结果缝合组与对照组的止血成功率无统计学差异(P>0.05);缝合组的止血时间及下肢制动时间明显较对照组缩短(P<0.01);对照组手术相关并发症发生率明显高于缝合组(P<0.05)。结论Starclose血管缝合器在老年冠状动脉介入诊疗中具有良好的临床效果和安全性。 Objective To assess the efficacy and safety of blood vessel suture device, Starclose, in coronary interventional procedure for senile patients. Methods Among the 204 senile patients who underwent coronary interventional procedure, Starclose was used in 110 who patients served as a suture group, and manual compression hemostasis was used in 93 patients who served as a control group. Hemostatic time, immobilization time of the lower extremities, and total incidence rate of operation-related complications in both groups were recorded, respectively. Results No difference was found in the success rate for hemostasis between the two groups (P0.05). The hemostatic time and immobilization time of the lower extremities were shorter in suture group than in control group (P0.01) while the operation-related complication rate was significantly higher in control group than in suture group (P0.05). Conclusion Starclose has a rather good efficacy and safety when applied in the interventional diagnosis and treatment of coronary heat disease of senile patients.
出处 《军医进修学院学报》 CAS 2010年第4期333-334,共2页 Academic Journal of Pla Postgraduate Medical School
关键词 冠状动脉疾病 外科缝合器 老年人 Coronary Artery Disease Surgical Staplers Aged
  • 引文网络
  • 相关文献

参考文献7

  • 1Campean L. Percutaneous radial artery app roach for conorary angiography [ J ] . Cathet Cardioacasc Diagn, 1989, 16 ( 1 ) : 327.
  • 2Kiemeneij F, Laarman GJ, Odekerken D, et al. A randomized comparison of percutaneous translurmnal coronary angiop lasty by the radial, bracial and femoral approaches : the access study [ J ] . J Am CollCardiol, 1997, 29 (6) : 1269-1275.
  • 3Ratnam LA, Raja J, Munneke GJ, et al. Prospective nonrandomized trial of manual compression and Angio-Seal and Starclose arterial closure devices in common femoral punctures [ J ] . Cardiovasc Intervent Radiol, 2007, 30 ( 2 ) : 182-188.
  • 4Jaff MR, Hadley G, Hermiller JB, et al. The safety and efficacy of the Starclose Vascular Closure System : the ultrasound substudy of the CLIP study [ J ] . Catheter Cardiovasc Interv, 2006, 68 ( 5 ) : 684-689.
  • 5Imam A, Carter RM, Phillips-Hughes J, et al. Starclose vascular closure device : prospective study on 222 deployments in an interventional radiology practice [ J ] . Cardiovasc Intervent Radiol, 2007, 30 ( 4 ) : 738-742.
  • 6Ikeno F, Sadoughi MA, Lyons JK, et al. Arteriotomy closure device application following percutaneous coronary intervention may prevent bleeding complications in patients with acute myocardial infarction [ J ] . Int J Cardiol, 2007, 117 ( 1 ) : 131-132.
  • 7Ruygrok PN, Ormiston JA, Stewart JT, et al. Initial experience with a new femoral artery closure device following percutaneous coronary intervention with glycoprotein lib/Ilia inhibition [ J ] . Catheter Cardiovasc lnterv, 2005, 66 ( 2 ) : 185-191.

相关主题

;
使用帮助 返回顶部